Dicas Reparação SONY




Modelo - Chassis


Pesquisa: SONY Enviar Dica Resolvida
Resultados 18938
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyICFD11W
MISSING GROUND JUMPER When frequency display button was pushed, frequency changedand the station was lost. This was the same problem as reported 2/16/82DK-2-1. It appeared to be a ground loop problem.
SonyICFC55W
LEAKY C115 Segment on right channel was not showing proper number. Allsegments lite up although a 1 should be shown. Found C115 leaky.
SonyICFC20W
DEFECTIVE Q4 AND Q5 Either Q4 was leaky or Q5 was open. AM on while switch inFM position.
SonyICF200W
OPEN R36 When the unit is turned on after a couple of minutes aclicking noise is heard at the speaker.
SonyCDP101
OUT OF ALIGNMENT High-frequency SQUEAL through audio system with CDP-101 inany mode (STOP/PLAY/PAUSE). Checked completely and looked at output withoscilloscope. No high frequencies were audible.
SonyCDP101
LOOSE RIGHT RAIL ON SLED Loose right rail on sled. Holder bracket missing.
SonyCDP101
DEFECTIVE CX-79034 Static noise in both channels after 8 to 10 minutes. Foundnoise being generated at output of CX-79034.
SonyCDP101
OUT OF ALIGNMENT Rumble in audio. Checked unit and found no problem. Problemcould be in software or playback system. Did complete alignment for unit,focus servo slightly out of range. Returned to customer.
SonyCDP101
SHORTED WIRE -10 volt line (from CN542 to CN536) was shorted to chassisnear bracket (bottom) to the rear of the sled assy.
SonyXR77
LARGE DISTORTION Unit produced large distortion during tape operation withoutboard display No. 'DPL -EL.
SonyTCK81
HIGH TORQUE MEASURED After installing new take-up arm assembly, forward torquemeasures 55 to 65 q/cn. This may be contributing to tape skew problems,by requiring increased back tension.
SonyTCFX33
PROBLEMS AROUND IC501 Unit will not lock into play mode and the service manualschematic does not agree with its own board layout in the book andneither agree with the board in the unit. -HQ COMMENTS: Release from play could be initiated by reset pulseor slow oscillator (R-C
SonyTCFX30
GROUNDING SPRING NEEDED Intermittent static noise was recorded when humidity levelsare low, erase and R/P heads were eliminated by grounding to chassis thisproblem occurs both on record and playback. -HQ COMMENTS: 1) Please apply grounding spring to erase head as outlinedin Ta
SonyTAN88
OPEN C410 The 78V line was reading about 110V on this unit and thesound was distorted. Adjusting RT401 had little effect. We found C410to be open and causing the problem.
SonyTAF55
SHORTED D406 The 15V line was down on this unit. We found D406 shorted(located in regulator circuit).


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads