Dicas Reparação SONY




Modelo - Chassis


Pesquisa: SONY Enviar Dica Resolvida
Resultados 18938
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyKV1947R
NO VHF, REPLACE IC002 Set had UHF operation but no VHF operation. No VC was presenton tuner. All switching voltages were correct and verified against aKV-1948R. Applying external DC to VC line tuned all stations.
SonyKX1901
LIGHTER RASTER ON THE TOP These units had a light area across the top of the screen.The first 12 to 15 scan lines after vertical blanking were lighter thanthe remainder of the raster. It looks like the units had a poor blacklevel just after vert. blanking. Also these units have
SonyKV1222R
INCORRECT MECHANICAL OPERATION The door assy will not stay closed due to the fact that thedoor retainer which is a plastic material, will not engage the catch onthe door securely in order to keep the door closed. This condition isprevalent on at least a dozen sets or more at the acco
SonyKV1221R
SHUT DOWN, REPLACED R001 After warm-up (or after simply plugging in and not turningon for 1/2 hour or so), the unit could not be powered up. If unit ison, it will then not turn off. Remote or manual same. IC001 was bad andthe relay drive transistor as originally suspected.
SonyKV1215
DEAD, REPLACED L309 While I was servicing the unit using an external DC powersupply, I noticed the absence of audio. Inspection revealed no 18Vbeing supplied to the SC board. Resistance of 18V line to groundmeasured about 1K ohms, should be about 180 ohms. I then found L
SonyKV1207
DEAD 12V line was being grounded by R221 lead touching ground.
SonyVTX1000R
INCORRECT TUNING OPERATION The customer complaint was the memory worked fine with theexception that it would not remember more than one channel beginning withthe number 3. It would remember any channel beginning with 3 but notmore than one.
SonyKX1901
NOISE LINES ON THE SCREEN There were several lines in the raster, about 2 inches downfrom the top, looked like retrace lines. These were present only whenthe set was cold after warmp up the lines would disappear.
SonyKV2649R
FM STATION RECEIVED WHEN OPERATING IN UHF MODE, IC002 FM music is received when a UHF station is selected. VL pinat tuner remains at +11 volts regardless of station selected.
SonyKV2647R
SNOWY PICTURE VHF, REPLACED VHF TUNER When switching to any low band VHF channel, the picturewould become snowy. Readjusting RF AGC control would eliminate theproblem. Then, changing channels again, the pix would be snowy again.This cycle could be repeated over and over again.
SonyKV2647R
PICTURE DISTORTION, REPLACE C-508 The symptom is that the raster will erratically demonstrateshort vertical sweep. It is very difficult to isolate the problem to anyparticular component due to symptom being intermittent.
SonyKV2645RS
JAIL BARS, REPLACED C539 Jailbars faint under normal viewing conditions. Problembecomes obvious when camera fades to gray, or picture and brightnesscontrols are placed at minimum. Jailbars are then observed in graduallylightening shades of gray from left to right across the CR
SonyKV2645RS
NO LAST CHANNEL MEMORY, REPLACED LEAKY D-26 ON MD BOARD Last station memory is lost when the set is turned off.
SonyKV2645RS
NOISE LINES ON THE SCREEN, REPLACED YOKE Lines visible at left side of screen, one inch wide andvertical. All channels exhibited the lines.
SonyKV1945RS
DEAD, WIRE SHORT TO GROUND Dead. Talking to customer, we found that it was intermittent.Finally the set failed to operate and it acted like high voltage shutdown problems becuase you could hear the high voltage come up and then godown. The key point here is that there were NO CH


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads