Dicas Reparação TOSHIBA




Modelo - Chassis


Pesquisa: TOSHIBA Enviar Dica Resolvida
Resultados 4731
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Toshiba2987DB
Service mode enteringPress and hold the MUTE button on the R/C, then at the same time, press the MENU button on the front panel.
Toshiba2987DB
Grey scale variesCheck 15k res on crt base
Toshiba2987DB
Excess Green driveReplace CRT Philips A68ESF002X116 Notes: You could adjust the G-DRV down so that the picture was watchable, but the hex value for the green drive was then 00, as compared to 84 or 90 for the other two guns.
Toshiba2939DB C2D
Field collapseTA8783N jungle IC faulty - had wrong readings on its o/p pins 32/37
Toshiba2939DB 3327DB
DARK BANDS DOWN EACH SIDE OF BRIGHT AREASC201 PIN 58 IC501 ( VIDEO IN ) 10uF 50v
Toshiba2939DB
STUCK ON STANDBYREPLACE ZP82 AND SOUND O/P IC501
Toshiba2939DB
STUCK IN STBY HT AT 45v ( COECT IN STBY )ICA01 MICROPROCESSOR U/S
Toshiba2939DB
POWER SUPPLY SHUTS DOWN , WORKS OK ON LOW CONTRASTL844 o/c , 8v SUPPLY TO CONSTANT CUENT CIRCUIT . COIL TYPE TEM2011 Pt No. 23103859
Toshiba2939DB
No sound/pic - blank rasterICS01 ( TA8211AH ) & ZP82 ( 2Amp fuse ) - speakers been messed with - blown audio
Toshiba2939DB
No sound from main spkrs - ok from ext surr sound spkrsTA8218AH IC on main board
Toshiba2939DB
Nicam int dropoutChange RD12 100k for 33k 1/2w, RD11 2k2 with 1k8 1/2w, CD18 22n with 47n
Toshiba2939DB
Int loses sync going from text to tv check settinIC501 TA8783n Pt No B0383970
Toshiba2927DB 3327DB 2539DB C2D
Frame bounce on channel change.R329 22K.
Toshiba2927DB ,
Stuck in standby.ZP82 OC. BECAUSE SUOUND SOUND IC. ICS01 SC ( ZP82 Toshiba 23144450 ICS01 Toshiba B0376856 ) ALSO IF ICS01 HAS FAILED REPLA
Toshiba2927DB ,
NO TEXTDA32 6.2v ZENER


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.