SintomaCausaSoluçãoPor:
Toshiba2505DB
Int loss of signalsDry joint 4Mhz Xtal in tuner
Toshiba2505DB
int blue mute screendry joints tuner
Toshiba2505DB
FIELD COLLAPSE WITH 4-5 FLYBACK LINES ABOVE THE LIIC371 TA8739P Pt No BO383680
Toshiba2505DB
Field - partial collapseC372 2µ 50v under IC371 had leaked & caused conductive path on pcb. Clean & replace C372
Toshiba2505DB
Dead with Audio Amp chips blastedCheck chopper Tx - may have s/c across windings supplying audio stage
Toshiba2505 , 2527
DOLBY SUOUND FAULTSEE Toshiba TEC BULLETIN
Toshiba2500TBT
POOR EW IC361 HOTD368 30v ZENER OC
Toshiba2500TBT
Field scan distortedC317 2µ2 50v
Toshiba2500TB5
CLOCK STOPS ON TEXT HOLDING PAGE SELECTEDDRY JOINTS ON XF01 ON TEXT PCB
Toshiba2500TB
VIBRATION FROM CABINETREFIT BUTTON ASSY. ADD FELT ( TAPE AVAILABLE FROM TEC DEPT ON REQUEST )
Toshiba2500TB
SEVERE CHROMA PATTERNING FROM COLD REDUCES AS SETC515 22uF OC
Toshiba2500TB
PICTURE VISIBLE FOR FEW SECS WITH SCAN FAULT THENR448 2.7ohm HIGH Toshiba 4984279 ( 12v TO TAA8659AN FALLS TO ABOUT 8v )
Toshiba2500TB
int clock stops on teletextresolder xtal XF01 13.875 on U101 text board
Toshiba2500TB
If chopper tr sc check R810 330k out of cctHt should be set for 145v
Toshiba2500TB
Field linC303 2µ2 50v in field drive near pin 32 TA8659


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.