Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
TOSHIBA | 140 U8 | vertical FECHADO TENSÃO DE 25V NORMAL | CI Q301 | ||
TOSHIBA | 2958GFS FS5 | vertical FECHA DO 5 SEGUNDOS DESLIGA | D301 ABERTO | ||
TOSHIBA | U10 | vertical SEMI FECHADO ABETO SOMENTE 10 Cm DO MEIO PARA CIMA. | C 301 E C 305 AMBOOS DE 1UF. | ||
TOSHIBA | U8 | vertical FECHADO | C 301 1Uf | ||
TOSHIBA | TVC 147 | vertical ROLANDO | R563 ALTERADO | ||
TOSHIBA | 1470 | vertical FECHADO COM LISTRAS FINAS NA PARTE SUPERIOR. | C303 2,2UF. | ||
SHARP | C-1417 | HORIZONTAL FECHADO (OU SEJA LISTRA BRILHANTE NO SENTIDO vertical) | C618 470n/250V ABERTO E R618 15R ABERTO. | ||
Philips | 20PT3336 | vertical FECHADO 5 SEGUNDOS LINHA PICA E DESLIGA | R3448 ABERTO | ||
PANASONIC | TC-29KL05 | LISTA NO SENTIDO vertical (OU SEJA) SEM DEFLEXÃO HORIZONTAL | C563 390n ABERTO. | ||
CCE | HPS-2004 | vertical Fechado | TROCAR C 405 (SMD) 2KPF/50V FICA NO PINO 42 DO IC 501 (TDA 8841) | ||
CCE | HPS-2981C | 1º- vertical Fechado 2º- Sem Vídeo | 1º - CI601 7809 estava com tensão em torno de 4 volts. 2º - Diodos D203, D204, D205 (1N4148) e o Transitor Q201 BC327 em curto | ||
CCE | HPS 1480 | vertical FECHADO R312 2,2R ALTERADO. | |||
GRADIENTE | 2021 | vertical abria parcialmente com linhas de | Se depois de verificar o vertical continuar verifique a eeprom | ||
TOSHIBA | TVC147-CR | Imagem balançando no sentido vertical | Diodo D820 da fonte de 9 volts | ||
TOSHIBA | TVC-147-CR | Imagem balançando no sentido vertical | Diodo D820 da fonte de 9 volts |