PhilipsMD2.21E
Curtain effect just after a white vertical line (ringing phenomenon)To reduce the ringing phenomenon change the following positions on the Small Signal Panel: Position 4508 into 1k (4822 051 10102) Position 3537 into 1k (5322 117 12487) Position 3538 into 1k (5322 117 12487) Position 3565 into 1k (4822 051 10102) Po
PhilipsMD2.12E
vertical lines bendedCheck the connection of the EHT cable inside LOT.
PhilipsMD2.12E
Curtain effect just after a white vertical line (ringing phenomenon)To reduce the ringing phenomenon change the following positions on the Small Signal Panel: Position 4508 into 1k (4822 051 10102) Position 3537 into 1k (5322 117 12487) Position 3538 into 1k (5322 117 12487) Position 3565 into 1k (4822 051 10102) Po
PhilipsMD2.12E
After a while vertical and horizontal scrolling picture.Check and replace if necessary: IC7505 (software) in the feature box. Software FBX3-F; 4822 900 10982 Software FBX4-Eco; 4822 900 10745.
PhilipsMD2.11E
vertical lines bendedCheck the connection of the EHT cable inside LOT.
PhilipsMD2.11E
Curtain effect just after a white vertical line (ringing phenomenon)To reduce the ringing phenomenon change the following positions on the Small Signal Panel: Position 4508 into 1k (4822 051 10102) Position 3537 into 1k (5322 117 12487) Position 3538 into 1k (5322 117 12487) Position 3565 into 1k (4822 051 10102) Po
PhilipsMD2.11E
After a while vertical and horizontal scrolling picture.Check and replace if necessary: IC7505 (software) in the feature box. Software FBX3-F; 4822 900 10982 Software FBX4-Eco; 4822 900 10745.
PhilipsMD1.2E
vertical lines bendedCheck the connection of the EHT cable inside LOT.
PhilipsMD1.2E
vertical black bars in 14:9 modeCheck soldering of C2403 on 16:9 PCB.
PhilipsMD1.2E
vertical amplitude of picture is too highChange item C2137 on the Small Signal Panel to: 2.2uF (10V) capacitor 5322 126 14103
PhilipsMD1.1E
vertical lines on left side in picture.Replace R3430/3431 (2K7; 0.33W) by 2K7 0.5W.
PhilipsMD1.1E
vertical bright stripe in picture.Check and replace if necessary IC7119 (TDA8366; 4822 209 90965).
PhilipsMD1.1E
vertical amplitude of picture is too highChange item C2137 on the Small Signal Panel to: 2.2uF (10V) capacitor 5322 126 14103
PhilipsMD1.1E
Picture not vertically locked.Check whether the sandcastle signal (pin 37 of IC7119) is locked on CVBS. If not, replace IC7119 (TDA8366; 4822 209 90965).
PhilipsMD1.1E
Noise in picture. vertical lines disturbedEHT cable was bad mounted in LOT.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.