Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
Philips | GR1-VA | NAO ABRE vertical | Verificar trilhas que passam do outro lado dos JUMPs 9558, 9237 e 9507 (trincadas), possibilidade do resistor 3229 estar aberto. * 05Jul96 JPBA *. Verificar 3417 (2k7) aberto. * 30Jul96 JPBA *. Verificar 3229 (1M) aberto. * 29Ago96 LT *. Ve | ||
Philips | GR1-R03 | NAO ABRE vertical | Verificar capacitor 2407 fuga. * 22Ago97 JPBA *. | ||
Philips | GR1-L1 2 | vertical COM POUCA AMPLITUDE | Verificar capacitor 2561 sem capacidade, ver tambem resistor 3426 alterado. * 03Set96 ANC *. | ||
Philips | GR1-L1 2 | NAO ABRE vertical | CABO DA UNIDADE DEFLETORA SOLDADO PELA ISOLAÇAO. * JUL 95 ANC *. Verificar capacitor 2417 (2200uF) com solda fria. * 03Set96 ANC *. | ||
Philips | GR1-L1 | vertical FECHANDO INTERMINTENTE. | CAPACITORES COM FUGA: 2406,2407 INTEGRADO 7410 DIODO 6410. * 94 ANC *. | ||
Philips | GR1-L1 | vertical DEFORMADO PARTES COMPRIMIDAS | CAPACITOR 2230. 94 JPBA. Resistor 3418 (1k) aberto. * Nov94 ANC *. Resistor 3417 (2K7) alterado. * 04Jan96 ANC *. | ||
Philips | GR1-L1 | vertical COM POUCA AMPLITUDE | RESISTOR 3426 (1,1) ALTERADO. * 93 JPBA *. CAPACITOR ABERTO 2230 (100nF). **. RESISTOR ABERTO 3418 (1K). * OUT 95 ANC * Resistor 3417 (2K7) alterado. * 04Jan96 ANC *. Resistor 3229 (1M) alterado. * 09Set96 ANC *. | ||
Philips | GR1-L1 | SEM SINCRONISMO vertical (VERT5). | RESISTOR 3556. **. CAPACITOR COM FUGA 2930 (100pF). * JUN 95 MJS *. | ||
Philips | GR1-L1 | SEM LINEARIDADE vertical. | APRESENTA TRAÇOS NAQ PARTE SUPERIOR 7200.**. RESISTOR ABERTO 3801 (1K). * OUT 95 ANC *. | ||
Philips | GR1-L1 | NAO ABRE vertical | VER ALIMENTAÇAO DO TDA8362, +8V NO EMISSOR DO TRANSISTOR 7205. * ANC *. DIODO ABERTO 6410. * MAI 95 CTR *. | ||
Philips | GR1-L1 | LISTA BRANCA. (vertical) | RESISTOR ABERTO AQUADAG 3556. | ||
Philips | GR1-L1 | IMAGEM DOBRADA NA vertical (I). | Drive 5505. * Ago94 JPBA *. Verificar diodo 6506 com fuga. * 18Set96 ANC *. | ||
Philips | GR1-L1 | DOBRANDO IMAGEM NO vertical | CAPACITOR 2415.* NOV 95 ANC * Resistor 3417 (2K7) alterado. * 04Jan96 ANC *. | ||
Philips | GR1-CLII | NAO ABRE vertical | C229 (15mF) SET 94 JPBA. | ||
Philips | GR1-CL | vertical CORRENDO (SINC2). | RETIRAR QUANDO HA PROBLEMA COM ANTENA. * OUT 94 INF DE OS *. |