Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
Philips | CTO-L | PIP NAO FIXA vertical | ALTERAR 3978 P/ 910 OHMS SUBSTITUIR 2970 POR UM JUMP | ||
Philips | CTO-L | DOS / MENU - CORRENDO vertical. | TRANSISTOR TS503 COM FUGA. * ANC *. | ||
Philips | CTO-L | COM RISCO ROXO vertical. | VERIFICAR IC 391 NO MODULO PIP. * 94 ANC *. | ||
Philips | CTO-C/L | NAO ABRE vertical | Capacitores C340/C343/C330/C307/C310.**. Diodo aberto D305.**. Resistor R470 aberto. * 15Mai96 CTR *. | ||
Philips | CTO | vertical FECHANDO INTERMINTENTE. | MAU CONTATO DE SOLDA FRIA EM C421 (2000uF). * JUL 95 ANC *. | ||
Philips | CTO | vertical COM POUCA AMPLITUDE | FUGA NO CAPACITOR C410. * JUL 95 CTR *. SOLDA FRIA NO CAPACITOR C421 (2000uF). * JUL 95 ANC *. | ||
Philips | CTO | SEM SINCRONISMO vertical (VERT5). | Capacitor C865 aberto. * 26Jan96 ANC *. | ||
Philips | CTO | SEM LINEARIDADE vertical. | CAPACITOR C407. * ANC *. Bobina defeltora U020 em curto. * 26Jan96 ANC *. | ||
Philips | CTO | NAO ABRE vertical | RESISTOR R404.**. CAPACITORES C406/C306/C408. **. CIRCUITO INTREGRADO IC400.**. Conf. Nov 95 CTR CIRCUITO INTEGRADO IC875.**. RESISTOR R590. * MAI 95 CTR *. POSSIVEIS SOLDAS FRIAS NO IC875 E IC400. * JUN 95 CTR *. Solda fria no ca | ||
Philips | ANUBIS-S | SEM LINEARIDADE vertical. | Verificar capacitor 2405 (10uF) e resistor 3405 (47). * 05Set96 IRHD *. | ||
Philips | ANUBIS 2 | vertical TREMULO (ONDULANDO) | Verificar capacitor 2415 aberto. * Nov95 CTR *. | ||
Philips | ANUBIS | vertical DEFORMADO PARTES COMPRIMIDAS | Integrado 7400. * Nov 95 ANC *. | ||
Philips | ANUBIS | vertical COM POUCA AMPLITUDE | UNIDADE DEFLETORA. * 13DEZ95 JPBA *. R3411, 3412, C2402. *18Set98 H.Desk* | ||
Philips | ANUBIS | vertical ABRE LENTAMENTE. | Verificar regulador 7218. * 15Out97 JPBA *. | ||
Philips | ANUBIS | SEM SINCRONISMO vertical (VERT5). | Verificar regulador 7218. * 10Out97 JPBA *. |