Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
Philips | 48VP41C | vertical CORRENDO (SINC2). | Verificar o EEPROM IC304 (SSP). *07Set98 H.Desk* | ||
Philips | 29SX8879 | vertical FECHANDO INTERMINTENTE. | vertical intermitente com eventual risco na tela, verificar D6742 e C2742(+12D). *31Ago98 SP606* | ||
Philips | 29SX8879 | vertical COM POUCA AMPLITUDE | Verificar capacitores 2740 e 2741. * 04Out96 MAN *. | ||
Philips | 29GX1895 | vertical FECHANDO INTERMINTENTE. | Mau contato 3405, ou 2405. * 02Fev96 JPBA *. | ||
Philips | 29GX1895 | SEM LINEARIDADE vertical. | RESISTOR 3405 ABERTO. * 13DEZ95 JPBA *. Obs.: Verificar possivel solda fria neste componente. * 23Set96 CTR *. | ||
Philips | 20PV471 | NAO ABRE vertical | R3531 (56R) aberto. *18Set98 CP160* | ||
Philips | 20CT6486 | SEM SINCRONISMO vertical (VERT5). | Verificar U009. * 26Jan96 ANC *. | ||
Philips | 17BL2002 | NAO ABRE vertical | TS522. 1529. | ||
Philips | 14PV461 | vertical FECHANDO INTERMINTENTE. | Verificar diodo 6513 e resistor 3531. * 31Mar97 JPBA *. | ||
Philips | 14PV461 | NAO ABRE vertical | Verificar resistor 3531 e diodo 6513. * 02Abr97 MJS *. | ||
Philips | L01.1L AC 29PT4631-25PT5531-29PT4640 | NÃO ABRE vertical - | Verificar capacitor 2407 fuga. | ||
PHILCO | TP-1452N | vertical FECHANDO INTERMITENTE | D702 | ||
PHILCO | CPH-05 | Deflexão vertical deficiente | R601 de 680K alterado | ||
PHILCO | PCS 2700 | imagem tremendo no sentido vertical | C 723 DE 2,2X 63 V | ||
PHILCO | PC2004 | SEM SINCRONISMO vertical E HORIZONTAL | C701 820PF |