Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | CTO-L | SO FICA EM STAND BY (POWER OFF). | D621 COM FUGA NAO APARECE MEDINDO COM INSTRUMENTO. * ANC *. | ||
Philips | CTO-L | SINTONIZADOR COM POUCO GANHO | SEM GANHO NA TELA GRANDE VERIFICAR CABO DO MODULO DE FI DE PIP ESTANDO QUEBRADO OU DESCONECTADO PROVOCA PERDA COM INTERFERENCIA VISIVEIS NO PADRAO DE BARRAS. OUT 94 ANC. RESISTOR R150 NO FI. * JUN 95 CTR *. UNIDADE FI (U140). * OUT 95 CTR * | ||
Philips | CTO-L | SINTONIA VARIANDO. | VERIFICAR UNIDADE FI U140/IC208 OUT 94 ANC. | ||
Philips | CTO-L | SEM SOM. (COM OU SEM IMAGEM P/ TV, VCR). | S186. * ANC *. SEM SOM NO PAINEL PRINCIPAL VERIFICAR INTEGRADO IC226. * ABR 95 JDCC *. | ||
Philips | CTO-L | SEM SOM EM LII (SAP) | U203 VEJA TAMBEM 20CT6557. JUL 94 ANC. Fuga no capacitor C042 (4N7). * 05Jul96 JPBA *. | ||
Philips | CTO-L | SEM SOM AO LIGAR | APARECE SOM APOS ACIONAR AV3 IC208. * OUT 94 ANC *. CAPACITOR C015. * MAI 95 ANC *. | ||
Philips | CTO-L | SEM SINTONIA. | IC208/IC204 TS104 COM FUGA. * ANC *. | ||
Philips | CTO-L | SEM SINCRONISMO H/V. | C305 COM FUGA. NOV93 JPBA . | ||
Philips | CTO-L | SEM PIP | TRANSISTOR TS514 VER TAMBEM U009. * JUL 94 ANC *. TRANSISTOR TS504. * SET 94 CTR *. CAPACITOR C015. * MAI 95 CTR *. Imagem fica deslocada, fuga C419. * 04Jan96 ANC *. Curto entre resistor 1e (linha do blank) e o terra, na placa REAR. * 11J | ||
Philips | CTO-L | SEM LINEARIDADE VERTICAL. | Verificar capacitor C346. * 02Abr97 MJS *. | ||
Philips | CTO-L | SEM BRILHO (VER TB.TELA1) | C370/C340/C291/C255/C430 IC201/IC200 TRILHA PARTIDA PROXIMO A R002 TAMBEM COMANDOS INOPERANTES OUT 94 ANC. Capacitor C280 (1uF) intermitente. * 08Jan97 ANC *. | ||
Philips | CTO-L | RUIDO INTERNO (MECANICA/VIBRAÇOES). (VER APIT3) | APARELHO FUNCIONA POREM SEM IMAGEM, VER LINHA DO +12VS, VERIFICAR PINO 2 DE T500, PODE ESTAR COM TRILHA PARTIDA. * OUT 95 ANC *. | ||
Philips | CTO-L | RGB COM BARRAS DE 60HZ. | Falta de Jump 246, enable do integrado de chaveamento. * 10Jan96 ANC *. | ||
Philips | CTO-L | QUADRO VARIA COM O BRILHO | VERIFICAR FUGA EM D542, A FONTE FICA BAIXA E A TELA SE TORNA CLARA COM BARRA VERTICAIS DEFORMANDO NAS LATERAIS. * JAN 95 JDCC *. RESISTOR R425 (5K6) ALTERADO. * AGO 95 ANC *. Diodos D543 e D573. * 11Jan96 ANC *. | ||
Philips | CTO-L | QUADRO PEQUENO | IC07 (PLACA DE SOM) OUT 94 ANC. |