Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | ANUBIS | NAO SAI DE STAND BY INTERMITENTE, OU NAO LIGA. | Verificar ajuste VO (95V), quando alto dispara o circuito de proteçao, ver resistor 3561 (56e). * 10Set96 ANC *. | ||
Philips | ANUBIS | NAO LIGA PELO CONTROLE REMOTO. | Diodo 6618 (BZX79 9V1) fuga, só ocorre com a tecla ON/OFF, pelos canais OK. * 26Fev96 HBG *. Ver 7636 (BC548). | ||
Philips | ANUBIS | NAO FUNCIONA (SO TELA COM CHUVISCOS). | CRISTAL 1630 (12mHz). * JUL 95 ANC *. | ||
Philips | ANUBIS | NAO FUNCIONA (FICA COMO DESLIGADO). | DIODO 6446 EM CURTO, (SAIDA H). * SET 94 EGS *. RESISTOR 3517, (3,3e), (fonte). * SET 94 EGS/CTR *. DIODO 6441 EM CURTO, (drive). * DEZ 94 JDCC *. VERIFICAR ESTAGIO VERTICAL (1449/7400/6416/2414/MCSS) CASO ESTEJA FECHADO, PROVOCA A PERDA DE C | ||
Philips | ANUBIS | NAO APARECE CARACTERES / MENU. | Verificar transistor 7635 (BC548B) com fuga. * 03Mar97 ANC* TS7634, S5720, C2721, C2722, IC7600, 7225 e Sand Castle. *18Set98 H.desk* | ||
Philips | ANUBIS | NAO ABRE VERTICAL | CAPACITOR 2415 ABERTO. * JUL 95 JDCC *. Capacitor 2404. * 29Ago96 JPBA*. Resistor 3403 (2k7) aberto. *02Out96 JPBA *. C2426, 2427, 2414, D6416, 6449, 1449, IC400, 7225, fonte de +26. | ||
Philips | ANUBIS | LINHAS DE RETORNO (RETRAÇO). | 7400 DANIFICADO POR PROVAVEL AUMENTO DA FONTE | ||
Philips | ANUBIS | LINHA FINA NO CENTRO (HORIZONTAL). | Solda fria no resistor 3448 (330E). * Nov 95 ANC *. | ||
Philips | ANUBIS | LED STAND BY NAO APAGA.(APARELHO EM ON) | VERIFICAR MICRO IC 7600 NA POSIÇAO DE SERVIÇO, QUANDO EM FUNCIONAMENTO PODE PISCAR DUAS VEZES E ATUAR COM CONTROLE OU PISCAR 5 VEZES E NAO OPERAR COM CONTROLE. * ANC *. | ||
Philips | ANUBIS | LED INTERMITENTE (ALEATORIO). | 1 PISCADA PROBLEMA NA RAM (MICRO) 2 PISCADAS LINHA DE DATA E CLOCK 3 PISCADAS EEPROM 4 PISCADAS PLL DO TUNER (VARICAP) 5 PISCADAS PROBLEMA DE LEITURA APOS ESCRITA (VER PROGRAMAÇAO/EEPROM) 6 PISCADAS | ||
Philips | ANUBIS | LARGURA DEFICIENTE | VERIFICAR RESISTOR 3512. * ABR 95 JPBA *. | ||
Philips | ANUBIS | INDICA ERRO (ER..). | ER6 = Ver capacitor 2512 (1mF). * Set94 ANC *. ER3 = Trilha partida do jump 9606 pino 6 do 7710. * 13Nov95 ANC *. ER5 = EEPROM 7710, ao mudar de canal a tela fica escura e volta para o canal inicial. * 13Dez95 ANC *. ER3 = INTEGRADO 7710. * | ||
Philips | ANUBIS | IMAGEM TREMULA (VER SERR1). | IMAGEM TREME AO AUMENTAR SOM, EXECUTAR BLINDAGEM EM 5525 E VERIFICAR INFORMAÇAO O6CT9405. Integrado 7510 (UC3842) no módulo da fonte. * 15Jan96 ANC * Verificar 3513, 3530, 6519, 5523 e 3517. * 26Jul96 ANC *. Diodo 6513 com fuga. * 23Set96 CTR | ||
Philips | ANUBIS | IMAGEM SERRILHADA (VER TREM1). | DIODO 6519 EM CURTO.**. Verificar modulo da fonte. * 05Jul96 JPBA *. | ||
Philips | ANUBIS | IMAGEM DOBRADA NA VERTICAL (I). | Solda fria no resistor 3448 (33OE). * Nov 95 ANC *. |