Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | 7CM3689 | DANIFICA SEMICONDUTOR IC OU TS | 7101 SUSB. TAMBEM 7106.**. | ||
Philips | 7CM3689 | BRILHO NAO ATUA | RESISTOR ABERTO 3339. * ANC *. | ||
Philips | 7CM3689 | APITA FORTE (FONTE), MAS NAO FUNCIONA. | Transistor 7106 (BD434) com junçao base e emissor alterada, pouca conduçao. * 26Fev96 ANC *. | ||
Philips | 7CM3299 | SEM LINEARIDADE VERTICAL. | Verificar integrado 2511 aberto. * 20Jun97 CTR *. | ||
Philips | 7CM3299 | CORES BORRADAS | RESISTORES 3370/3366/3340 .**. | ||
Philips | 7BM749 | VERTICAL CORRENDO (SINC2). | Verificar capacitor C422. * 17Jan97 FR *. | ||
Philips | 7BM749 | TELA OSCILA NO SENTIDO HORIZONTAL. | Verificar capacitor C135 aberto.. | ||
Philips | 7BM749 | TELA ESCURA "PRETA" (VEJA TAMBEM BRIL4). | VERIFICAR RESISTOR R313 VALOR INCORRETO OU ALTERADO. * MAR 95 JO *. Verificar 3131 aberto. * 27Mai96 CTR *. | ||
Philips | 7BM749 | SEM SINCRONISMO VERTICAL (VERT5). | Verificar ajuste no R422. *01Set98 H.Desk* | ||
Philips | 7BM749 | PERDE SINC. HOR. AO MUDAR CENA OU RESOLUÇAO. | INTEGRADO IC401. * JUN 95 ES *. | ||
Philips | 7BM749 | NAO FUNCIONA (FICA COMO DESLIGADO). | 7104 EM CURTO. *94*. 3102 Q104 VER R103/R104. NAO FUNCIONA, POIS AO LIGAR ATUA A SOBRETENSAO, POSSIBILIDADE DE D109 ESTAR COM FUGA. * DEZ 94 ANC *. Verificar 7101 aberto. * 11Jan96 CTR *. Verificar resistor 3103 aberto. * 04Jul96 CTR *. | ||
Philips | 7BM749 | NAO ABRE VERTICAL | Capacitor C428 aberto. * 25Abr96 LAV *. | ||
Philips | 7BM749 | IMAGEM TREMULA (VER SERR1). | Verificar capacitor 2508 com fuga. * 13Jlu97 FR *. | ||
Philips | 7BM749 | DESLIGA INTER. OU PROTEGE (REW 3 P/ VCR). | VERIFICAR C112 ABERTO. * DEZ 94 ANC *. D109 COM FUGA. * DEZ 94 ANC *. | ||
Philips | 7BM749 | DANIFICA SEMICONDUTOR IC OU TS | IC502 DANIFICA AO LIGAR, VERIFICAR CABO DE AQUADAG DO TRC OU TRC. OBS.: NAO LIGAR APARELHO SEM A BLINDAGEM DA PLACA TRC. PONTO DE ATERRAMENTO DO TRC NO MONOPAINEL FICA PARALELO AOS COMPONENTES R504 E C502, QUANDO ESTA COM ESTE SINTOMA HA UM FAI |