Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDV801 | NO LANC OPERATION/NO REMOTE FUNCTION - W201 COLD SOLDER | RM95 not powering up/no function when connected to remoteconnector and no remote control function. | ||
Sony | CCDTRV70 | NO PIX ON THE SCREEN /RESEAT CN102 | No picture on the LCD screen. Camera does not accepet EVF EVR data's. Found CN102 unplugged on PD-62 board. | ||
Sony | CCDTRV30 | NO ZOOM/ MAIN FLEX #553 TORN | Zoom not working | ||
Sony | CCDTRV30 | NO AUDIO/ RECONNECT CN302 AU185 | No audio at all | ||
Sony | CCDTR80 | BATTERY END ADJUSTMENT DATA ADDRESS IS INCORRECT IN S/M | When setting up to read data for battery end adjustment,value at address 47 does not change per procedure on page 7-62 of servicemanual. | ||
Sony | CCDTR5 | NO REC ON CAMERA/CAUTION MODE IN FF- REPLACE CASSETTE HOLDER | Camera section cannot rec on VTR section, when you FF theunit will go into caution mode, found cassette holder bad. | ||
Sony | CCDTR5 | DARK PIX IN CAMERA/NO CHARACTER DISPLAY IN VF/CN802-VC60 | Unit has dark pix in e-e on camera section and no charactersyn. Found Cn802 on VC60 loose. | ||
Sony | CCDTR400 | BATTERY END ADJUSTMENT DATA ADDRESS IS INCORRECT IN S/M | When setting up to read data for battery end adjustment,value at address 47 does not change per procedure on page 7-62 of servicemanual. | ||
Sony | CCDTR101 | NO FUNCTION POWER OK- IC924/VC103 | Unit was tampered with by other service dealer. Unit did notfunction, no camera or vtr. Found IC924 mode control ic bad The ic onlyinitialized reset, no power on vtr/camera on line. | ||
Sony | CCDTR101 | INTERMITTENT POOR EJECT/ M902 | When power is restored on vtr/camera, found mechanism problemon emergency mode. I can load and eject tapte but sometimes on eject, itejects out 2/3 then stops found capstan not turning. -SOLUTION :Replace a used capstan M902, restored unit to normal. | ||
Sony | CCDFX630 | RAINBOW COLOR DISTORTION/IC505 VS110BD RESOLDER | Rainbow color distortion when recording over old recordings(FE head is not working) Found problem to be intermittent whendisassembled, pressed on VS110 board, found problem to be cold solderedIC505. (FE on command int.) | ||
Sony | CCDFX630 | NO RECORD/ #117 SWITCH BLOCK CONTROL | Unit would not record, everything else ok. Resoldered IC505,a couple of times, still no rec. I noticed using a remote, unit wouldhave vtr functions when in cam mode, this lead me to vtr/cam sw. | ||
Sony | CCDFX530 | NO EVF/SHUTDOWN PROBLEM/ IC501-VF44 | No video in viewfinder, camera will the shutdown. Appears tobe a syscon problem, but camera will work fine when viewfinder isdisconnected. The 5 volt line to evf is loaded down when connected. | ||
Sony | CCDFX510 | INTERMITTENT COLOR/ X301- VA-74BD | Received a few reports of intermittent color. Problemoften goes away if case or board are slightly stressed. Problem causedby intermittent color crystal, X301 on VA74 board. When in failure modefrequency of operation is around 5 mhz. Replacing re | ||
Sony | CCDFX510 | NO COLOR IN PLAYBACK/IC301-VA74 PIN 14 RESOLDER | No color in playback. |