SonyTAM2000ANY PHONE HOOKED UP TO MACHINE IS DEAD - REPLACE Q301 Unit would not power up and also was shorting line (dialtone), making any phone hooked to unit appear dead. This occurred evenwith TAM2000 unplugged from AC adapter.
SonySPPX90DIFFERENCE BETWEEN MAIN BOARD (OLD AND NEW) The tech ordered main board p/n A-3615-557-A, the new board ismade in Japan, the old board is made in Taiwan. The following are thedifferences Jack connectors CN-601, 602, 603 and 502 are different,connectors don't fit, also the new board has two extra c
SonySPPX90THE LINE LAMP WILL NOT TURN OFF - REPLACE Q602 (872912028) The line lamp will not turn off. The relay/led drivetransistor Q602 is defective. There is 1.9v at collector of Q602 (itmust be 5.2v).
SonySPPX50NO RANGE (TX BASE) - L401 MISSING IN BASE Unit has poor reception, range, and found missing L401 antcoil, (looks like it was not installed in the factory).
SonySPPQ405HANDSET CUTS IN AND OUT DURING C0NVERSATION Handset cuts in and out during conversation. Battery terminalsin handset were not making secure contact with the battery. They wereeither bent out of shape (due to pressure exerted by battery when pushedin), or desoldered. If ref 16 (battery terminal) is
SonySPPQ400HANDSET CUTS IN AND OUT DURING C0NVERSATION Handset cuts in and out during conversation. Battery terminalsin handset were not making secure contact with the battery. They wereeither bent out of shape (due to pressure exerted by battery when pushedin), or desoldered. If ref 16 (battery terminal) is
SonySPPQ210HANDSET CUTS IN AND OUT DURING C0NVERSATION Handset cuts in and out during conversation. Battery terminalsin handset were not making secure contact with the battery. They wereeither bent out of shape (due to pressure exerted by battery when pushedin), or desoldered. If ref 16 (battery terminal) is
SonySPPQ210LOW BATTERY AFTER CHARGING. Customer states they have low battery after charging for longtime.
SonySPPQ200HANDSET CUTS IN AND OUT DURING C0NVERSATION Handset cuts in and out during conversation. Battery terminalsin handset were not making secure contact with the battery. They wereeither bent out of shape (due to pressure exerted by battery when pushedin), or desoldered. If ref 16 (battery terminal) is
SonySPPQ200LOW BATTERY AFTER CHARGING. Customer states they have low battery after charging for longtime.
SonySPPQ105HANDSET CUTS IN AND OUT DURING C0NVERSATION Handset cuts in and out during conversation. Battery terminalsin handset were not making secure contact with the battery. They wereeither bent out of shape (due to pressure exerted by battery when pushedin), or desoldered. If ref 16 (battery terminal) is
SonySPPQ100HANDSET CUTS IN AND OUT DURING C0NVERSATION Handset cuts in and out during conversation. Battery terminalsin handset were not making secure contact with the battery. They wereeither bent out of shape (due to pressure exerted by battery when pushedin), or desoldered. If ref 16 (battery terminal) is
SonySPPER1TESTING BATTERY CHARGING SYSTEM On previous models the charge light would come on if thecontacts were momentarily shorted. Not on this model. Placing aresistor 10 to 100 ohms, across battery charging terminals causes thelight to come on for a short period. This is useful if unit
SonySPPA60INTEMITTENT OR NO TRANSMIT - REPLACE L512, P/N 1-402-757-11 Unit would only transmit sporadically. Tapping on board causedno transmit.
SonySPPA5000FACTORY PRERECORDED GREETINGS ARE DISTORTED Factory prerecorded greetings and instructions sounddistorted. There is excessive wow and flutter in the audio, possiblycaused by an incorrect sampling rate (too low) in A/D and D/A conversions.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.