Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDTR80 | NO COLOR ON RECORD OR PLAYBACK / REPLACE X201 | Camera had no color through the monitor, but pix in EVF wasOK. Discovered frequency of VXO 40 Hz lower. | ||
Sony | CCDTR73 | NO PIX CAMERA MODE / RESLDR X701 OFF TIMING GEN IC702 | No picture in EVF or line out during camera mode, justflickering and noise. Found oscillator at timing generator IC702 coldsoldered, producing erroneous frequency. | ||
Sony | CCDTR73 | NO PIX IN VF / RESLD CN203 ON VS BOARD | No pix in playback and rec. | ||
Sony | CCDTR73 | NO PLAYBACK PIX / REPLACE C1167 ON THE HE19 BD | No playback pix, audio ok. | ||
Sony | CCDTR73 | VIEWFINDER INOPERABLE/INPUT DATA IN PAGE "D" ADD'S BO TO BB | No color in viewfinder. | ||
Sony | CCDTR71 | DEAD / LIT BAT RESET | Unit came in dead, has display no batt indicator, nofunctions. -SOLUTION :Removed lith batt ran unit then reinstalled lith batt. Letsit overnight, still worked next am. have seen this in 2 other CCDTR71,is there amod like in the FX series for lockup | ||
Sony | CCDTR700 | COLORS ARE CHANGING / ZERO OUT DATA, PAGE "F" ADD 6B; WAS F1 | After comparing data with a working unit, found address 6B ofpage F to be F1 (AWB all tracking mode), changed data to 00 to restorethe normal mode of AWB operations. | ||
Sony | CCDTR700 | DIST/LOW AUDIO ON LEFT CHANNEL / REPL D519 ON THE JK-108 BD | Unit had very low and distorted audio on the left channel. | ||
Sony | CCDTR700 | DEAD / REPLACE F450 & F452 | Unit not powering on VTR/Camera. Found F450, F452 badcaused by drop of unit. Unit also has bend in cassette holder and brokenpart caused by impact of drop. | ||
Sony | CCDTR700 | CASSETTE HOLDER NOT CLOSING / REPLACE SLIDER (T) ASSY | Cassette holder is not closed and that's why the unit cannotaccept tape. Found Plate assy side broken caused by a drip. -SOLUTION :Replace (T) assy side. | ||
Sony | CCDTR70 | INDIVIDUAL MOTOR TESTING USING RM-95 | Models such as the CCDTR400 and CCDFX430 do not include themotor test on one of the service procedures, ex, capstan forward andreverse drum forward and reverse etc. | ||
Sony | CCDTR70 | NO COLOR ON RECORD OR PLAYBACK / REPLACE X201 | Camera had no color through the monitor, but pix in EVF wasOK. Discovered frequency of VXO 40 Hz lower. | ||
Sony | CCDTR61 | SLOW/POOR AF WHEN CHANGING ZOOM POSITION / CLEAN ZOOM POT | Received a number of reports from Best Buy of slow/poorautofocus when changing the zoom position of the lens. Problem due todirty zoom potentiometer. Dirty control does not provide correct feedbackto the CP. Auto focus program does not run correctly. | ||
Sony | CCDTR61 | NO CAMERA CHROMA / L721 OPEN | No cam c signal present at pin 12 of W405 on VC133 board.Good cam c singal at pin 30 of IC707 camcore. | ||
Sony | CCDTR600 | NO PIX CAMERA MODE / RESLDR X701 OFF TIMING GEN IC702 | No picture in EVF or line out during camera mode, justflickering and noise. Found oscillator at timing generator IC702 coldsoldered, producing erroneous frequency. |