Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CFS1035 | UNIT WILL NOT PLAY OUT ONE OF THE SPEAKERS - RESOLDER J303 | Unit will not play out of one of the speakers. Found phonejack J303 poorly soldered. | ||
Sony | CFD616 | DISC DRAW DOESN'T OPEN | CD door won't open because T lever (ref 225) isbroken/misalighed. May be result of customer pulling out cd door toohard. | ||
Sony | CFD560 | IC702 DIFFERENT FROM S/M | Unit had a KA8309 p/n875906138 as IC702 on the board. Svcrordered 875203748, CXA1182QZ, as indicated in s/m and it doesn't work atall. See previous FPR for original problem. I don't have copy of news/m/995908812 that is indicated in FPR P1668. Does | ||
Sony | CFD560 | CD BUTTONS DO NOT FUNCTION | Get either no ams/search forward or reverse, no play etc. | ||
Sony | SLV420 | POWERS ON/OFF BY ITSELF CONTINUOUSLY - REPLACE CAPSTAN MOTOR | Hit power button, unit turned on for one sec, then off for one sec and the cycle would continue | ||
Sony | EVA50 | LOADS W/OUT CASS WHEN FIRST PLUGGED IN - REPLACE S302 SWITCH | When unit is first plugged into ac outlet, tape guides move to loaded position with display indicating cassette in, then powers off. | ||
Sony | KV32XBR37 | INTERMITTENT DATA/REPLACE IC102 M BD/WRONG PART LISTED | Page 92 of S/M has IC 102 listed incorrectly. The actual part is a ST24C02CB1 and should be listed as 875928074. - HQ COMMENTS: We will check into this and issue a Service Bulletin. | ||
Sony | KV32S15 | Q601/Q602 FAILURES, REPLACED C609 | Unit had shorted convertors, were replaced and set returnedafter checking on bench. Failed again after a few days. This timeVDR601, 602, 603, D603, D605, R607, R644, R611, and R612 were changed,along with Q601/Q602. Unit ran 3 days and failed again on st | ||
Sony | KV27XBR95S | HORIZONTAL BAR IN PIX, REPLACED C1505 | Unti came with horizontal lines(bars) in picture. After warm up,was able to trace problem to defective electrolytic capacitor C1505. -HQ COMMENTS C1505 is located at IC1501/pins 3 and 6. Schematic gridlocation L-11. | ||
Sony | KV27TS36 | DEAD, REPLACED IC602 | Unit came in with blown P/S. Repaired supply and set wasstill dead. No reset getting to micro. | ||
Sony | KV27TS32 | DEAD (NO MICRO OPERATION), REPLACED IC602 | Set had blown P/S. After repairing supply set would still notcome on. Found no reset getting to the micro. Traced to reset IC. | ||
Sony | KV27S15 | NO PICTURE, REPLACED R526 | No picture, turning screen control would get retrace linesand dim picture. Turning screen control back again picture would benormal unitl the set was turned off and back on again, then no picture.Servicer replaced IC301 on M board as voltage on pins | ||
Sony | KV2553MT | POWER ON AFTER FUSE REPLACEMENT, SEE SB # 199 | Set came in with the above part open. This is the fuse tothe 14v supply. Tech attemped to turn on the power with the button onthe front of the unit. Set would not power up, and standby light came on. In attempting to diagnose problem, nothing could be | ||
Sony | KV20VM20 | INTERMITTENT TAPE PLAY, SOLDER SHORT ACROSS RS01 | Tape would play for app 30 sec and shut down. Rewind andfast forward also would react the same. | ||
Sony | KV20VM20 | DEAD, REPLACED IC1801, F1802, AND ZD1008 | Unit had no power. |