Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CDPC745 | CD DRAWER INOPERABLE - REPLACED ROTARY GEAR | Drawer won't open because rotary gear ref. 56, part #495728401, will not allow carousel to make a complete revolution. | ||
Sony | CDPC335 | BROKEN POST FOR LEVER REF #111 - SEE S/B HFP 365 | Post for set lever ref #111 breaks from chassis causingdrawer problems. | ||
Sony | CDPC245 | INTERMITTENTLY DOES NOT RECOGNIZE DISCS | Intermittently, unit will not recognize disc. Occurs inshuffle mode or checking discs. Unit will load and chuck discs w/oproblem. No problem with alignment as describe in SB CSA13/#390.Turntable appears to rotate a bit too fast. Logic from disc sen | ||
Sony | XRU330 | INTERMITENT OR NO AUDIO (FOUND COLD SOLDER ON R118 AND R120) | No audio or intermittent audio. Found cold solder joints onR118 and R120. | ||
Sony | XRU220 | INTERMITENT OR NO AUDIO (FOUND COLD SOLDER ON R118 AND R120) | No audio or intermittent audio. Found cold solder joints onR118 and R120. | ||
Sony | XRC410 | TAPE EJECTS SOON AFTER LOADING (CLEANED OIL ON REEL SENSORS) | Unit takes tape in, plays for 15 secs., then ejects tape.Opened mech and found a drop of oil on one of the reel sensors on reelsensor board. | ||
Sony | XR430 | UNIT DEAD (FOUND BROKEN GROUND BETWEEN CN551-8 & D553/D554) | Unit dead, would power up with 13.5 - 14 volts applied,however below 13.5 unit would not respond. Note: compared this unit to anXR340 and the XR340 powered up below 12 volts. | ||
Sony | XR3050 | LOW VOLUME LEVEL (REPLACED DEFECTIVE AUDIO CONTROL IC411) | Volume would not increase on outputs, but display numberswould. | ||
Sony | XM260G | SERVICE MANUAL CORRECTION: Q152 REGULATOR | Q152 collector and emitter connections are drawn incorrectlyin service manual. | ||
Sony | XDPU50D | WON'T RECOGNIZE 2 CHANGERS AT ONCE (FOUND IC701 DEFECTIVE) | When changer was plugged into Unilink control 1 or Unilinkcontrol 2, unit would work fine. If two changers were connected in bothcontrol 1/2 unit would not recognize either of them. Scoped waveforms andvoltages, could not see any loading down of data | ||
Sony | MDX400 | DISTORTED AUDIO ON MINI DISC (REPLACED IC302 AND IC305) | Audio was distorted and sound was gargled. | ||
Sony | MDX100 | WOULD NOT PLAY MO OR CD (REPLACED IC505 AND IC507) | Intermittently, unit wouldn't play any disc. When it didplay, you would hear various interruptions in audio. | ||
Sony | CDXT60 | PART NUMBER FOR CDXT60 MECHANISM OPERATIONAL MANUAL | Part number for CDX-T60 mechanism operational manual will notaccept by FIPM screen. Part number printed on back of manual is9-959-796-31. Need correct part number.Please call 810-347-3370, or Fax 810-344-4899. -HQ COMMENTS: NPC has told us that this m | ||
Sony | CDX5040 | POPPING DURING MODE CHANGE FM, AM OR CD (REPLACED Q102) | Changing from FM1 or FM2 or AM & CD there would be a loudpop in the rear output. | ||
Sony | CDX4090 | NO AUDIO OUTPUT (FOUND Q593 DEFECTIVE) | Found no audio output from unit. Found Q593 not switchingB+ on unit. |