Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | SLVR5UC | MISPRINT IN RECORDING CHROMA ADJUSTMENT | The measurement point for making the Record Chroma Adjustment(1-4-13, page 12 of Supplement 1), is listed as pin 6 of IC-033 on theVC-92 board. There is no IC-033 on the YC-92 board. | ||
Sony | CCDTR7 | IMPROPER DATE/TIME FUNCTION | When displaying time function, the seconds would count onceevery 5 to 10 seconds. | ||
Sony | KV27XBR15 | NO PICTURE MIGHT HAVE DISTORTED SOUND, COLD SOLDER HDT | Unit was inoperable. Traced problem to cold solder connectionon HDT. | ||
Sony | KV27XBR15 | DEAD, REPLACED FBT AND Q-503 | Set was inoperable. Replaced Q-503 which shorted and poweredup set and took Q-503 again. Traced problem to T-500 FBT defective. | ||
Sony | KV27TS30 | PICTURE ALL MESSED UP/BRIGHTNESS/COLOR, REPLACE R-587, D-518 | Picture was all messed up, brightness and color. Traced pro-blem to burned R-587 and found D-518 G-2 rectifier diode bad. | ||
Sony | ITA205 | NO POWER ON | No power on. | ||
Sony | CCDF35 | NO COLOR ON RECORD | In camera mode record picture goes to black and white. Thisoccurs after 5 to 10 minutes, when the unit warms up. | ||
Sony | CCDF33 | IRIS OPENS AND CLOSES FAST | Iris would open and close fast (chatter) with lens cap removedand camera turned on. | ||
Sony | STRGX10ES | PROBLEM FOLLOWING INSTALLATION OF MOD - S/B NO. HFP0102R1 | After installing modification to correct tuner bleed through,I found that when selecting any video for an audio source the tuner LEDwould glow dimly. | ||
Sony | STRGX9ES | PROBLEM FOLLOWING INSTALLATION OF MOD - S/B NO. HFP0102R1 | After installing modification to correct tuner bleed through,I found that when selecting any video for an audio source the tuner LEDwould glow dimly. | ||
Sony | KV27TW70 | WEAK COLOR, ADJ RV-501 FH CONTROL | Set had weak color on all channels. | ||
Sony | CFS203 | PART NUMBER ADDITION, PLATE, LCD (TRANSPARENT) | The picture of the front cabinet assy. in the exploded viewsimplies that the transparent LCD plate (which covers the LCD display) ispart of the cabinet. However, this is not true. The plate must beordered separately. | ||
Sony | SLV757UC | BLUE SCREEN ON EE PICTURE WHEN FED FROM 8MM DECK | Customer was using a CCD-F70 feeding the video inputs of theSLV-757UC. Output of the SLV unit fed a monitor. Whenever user used thehigh speed scan on the camera, the EE video went to a blue screen.Servicer noted that the video level from the camera dro | ||
Sony | SLV555UC | BLANK OR BLUE SCREEN DURING SOME 8MM MODELS SCAN MODE | During scan modes of various 8mm models, the unit may blank,distort the picture or present a blue screen. | ||
Sony | TCDD3 | WARRANTY PERIOD | What is the correct warranty period? The warranty book onpage 28 states 90 days labor and one-year parts. The CIC computer showslabor and parts 1 year. -HQ COMMENTS: Tokyo states the warranty period of the TCD-D3 as 1 yearparts and 90 days labor. |