SonyKV1746R
REPLACEMENT VERTICAL OUT IC UPC1358H is substituted by UPC1488H (8-759-113-05) in verticaloutput in KV-1746R. Servicer says he tried two of the subs. ICs bothtimes got the results of the picture included. He states he got a hold ofthe original IC UPC1358H and after replacement p
SonyCCDV5
CONTINUOUS CAPSTAN/DRUM MOTOR RUN As soon as power was applied to unit, the capstan and drummotors would start running, and not shut off. Troubleshooting revealedthat Q-504 and Q-507 on the (SS-70) bd. would never turn off. The emittervoltage on these transistors was running approx. 7.
SonySTRAV380
NO AUDIO OUT No output audio, signal traced to input on IC-502 (input bd.)but no output, chip IC-502 had been replaced. Checking signals - noticedspikes on data line, problem traced to IC-302.
SonySSU520
SERVICE MANUAL CORRECTION Service manual lists part number 1-4919-676-11 for the grill.The correct part number is X-4919-676-1. This info is from Dale in theKansas City SSC. Please issue correction. -HQ COMMENTS: You are correct. Also not that the Sony logo part numbershould
SonyXM120
UNIT GOES INTO PROTECTION MODE Right channel lower in volume. Unit goes into protection modeunder extreme conditions or when under heavy load. Also S/N 25134 and32009.
SonyXK8D
SYSTEM SHUTS DOWN WHEN POWER LOCKS OR HORN ACTIVATED IN VAN Units are new installs in a van. When the horn is blown orthe power locks are activated, the units shut down. Have to re-power theunit. If you unplug the XK80 remote wires to the CDX-R88 unit, it willnot lock up when horn or power locks are activated.
SonyCDXR88
SYSTEM SHUTS DOWN WHEN POWER LOCKS OR HORN ACTIVATED IN VAN Units are new installs in a van. When the horn is blown orthe power locks are activated, the units shut down. Have to re-power theunit. If you unplug the XK80 remote wires to the CDX-R88 unit, it willnot lock up when horn or power locks are activated.
SonyCDXR88
DISTORTED RIGHT CHANNEL Distortes right channel audio. It sounded hazy.
SonyXR7150
SQUEALING NOISE WHEN TAPE CHANGES DIRECTION Technician at San Jose SSC advised me of this problem. Whentape direction changes, unit makes a squealing sound. He has not locatedthe problem, but has eliminated it by connecting a 10mFD electrolyticcapacitor from pin 4, CNP-909, to ground. This is t
SonyCDPC7ESD
PGM PLAY SKIPS DISK After programming, order of playback everyother disk isskipped.
SonyKPR4110
WEAVING PICTURE, REPLACED IC-5007 (E BOARD) Picture had a slight weave that moved from bottom to top. Allinput sources displayed except the ON screen displays.
SonyCCDV3
OPERATION MANUAL ERROR/PAGE 154/TABLE 7-5 On table 7-5, page 154 correct the columns headings to readfrom left to right: K00 (IC301 (13) ) K01 (IC301 (14) ) K02 (IC301(15). Also change REW to FF and FF to REW. Do not change the Sw. Ref.Nos. - they are printed in the correct location.
SonyCCDV9
NO CHARACTERS GENERATED IN EVF Found no characters generated to EVF but LCD display ok.
SonyD4
WILL NOT TRACK DISC PAST SECOND TRACK Unit would start mistracking on track No. 2 (3:00 on display).
SonyCCDM8U
EATS TAPES Unit ejects half way then stops. Sometimes will eject buteats tapes.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.