SonyKV1911
SEVERE PIN CUSHION Severe pin cushion, pulled in 2-3 inches on each side.Checking 15 volt line found a negative H pulse on the line. Found C810to be open.
SonyKV1747R
SETS WILL NOT LOCK ON CABLE CHANNELS Set will not lock on cable channels. Usually the 47 modelsand models with a similar chassis. I tried reducing the value of C208but this made the problem worse. We tried increasing the values of thiscap and found that the sets would perform properly wi
SonyKV1747R
CHANNEL LOCK When changing channels, up/down with remote, unit would lockon channel 8 for approx. 8 to 10 seconds. Unit would scan up/down allother channels with no problem.
SonyKV1547R
PICTURE BLANKS Set would play 15 mins., then would start blanking in and out.Vertical would then start shrinking and soon would collapse.
SonyKV1520R
NO VOLUME CONTROL This unit had no volume up. We found D1117 to be ever soslightly leaky.
SonyKV1355R
UNIT GOES SHUT DOWN MODE, CRACK ON BOARD Any movement of cabinet would cause the set to go intoshutdown mode. I defeated the input to the shutdown circuit, Pin 17 ofIC501 to prevent shutdown in order to isolate the problem. The voltageat Pin 16 of IC501 would increase when the problem occurre
SonyKV1221R
INTERMITTENT TURN OFF, REPLACED IC001 This unit would intermittently turn off. We found the remotedecoder IC (IC001) to be thermally sensitive.
SonyKP5040
NOISE BAR IN THE CENTER OF OTHE SCREEN, CONNECTION CHANGE A vertical bar appeared in the center of the picture whenviewing a normal program. Investigation of the circuit revealed that theLOT transformer pulse seen at Pin 1, of T504 on the E board wasdisplaced from its normal in phase relationship to the flybac
SonyKP5040
MECHANICAL INCORRECT OPERATION, REPLACED IC6501 Drive voltage to the mirror door motor would not be removedonce the door had reached its end of travel. Instead, the drive motorwould continue to ratchet.
SonyFD20A
INTERMITTENT POOR FOCUS, REPLACED CRT This unit had intermittent focus. The focus voltage wouldgo up to 900 volts.
SonyKX2501
PIC DISTORTION ON CH 7, ADD GROUND BETWEEN "C" AND CHASSIS Oscillation left side of CRT, 1 wide, appeared on channel#7 only.
SonyKV8100
UNIT SHUTS DOWN When turned on, unit would shut down. Isolated problem tothe 22 volt line. It was reading 27 volts. Found Q602 regulatordriver leaky.
SonyKV3000R
UNIT COULD NOT BE POWERED ON Unit could not be powered on. Inspection revealed lack of12 volt DC to control circuits.
SonyKV2650RX
NO PICTURE, REPLACE IC002 VC voltage on chs. 2/3/4 was low - below 2 volts. Chs. 5/6and all others were fine. Found 4 volts at Pin U on tuner.
SonyKV2647R
PICTURE DISTORTION, REPLACE C508 Vert. foldover and decreased vert. deflection becausecapacitor (C508) failed. This same capacitor is also failing in othermodels and quite frequently.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.