GrundigCUC3490Field fault - non lin with top missingPin 2 field chip only 12v (24v) C411 1000µ 50v supply smoother u/s
GrundigCUC3490dead no line drive or htTR651 mains tfmr pins 1-15 o/c, pins 15-17 s/c
GrundigCUC3490Dead - chopper tr s/c, HT fuse o/cDry joints pin 5 daughter board
GrundigCUC3490Dead - chopper tr s/c & fuse o/cC667 2µ2 (2 caps) dry joints or low cap
GrundigCUC3490Deado/c HT fuse; s/c chopper tr; sus dry joints pin 5 of daughter pcb
GrundigCUC3400Tripping comes on if adj line frequency down.C653 ( 4.7u f )
GrundigCUC3400trippingset ht pot R637
GrundigCUC3400Startup - No s/up - ticking from transformer.C653 ( 4.7nf ) connected to pin 15 of IC.
GrundigCUC3400Poor R/C responseR1212 33R missing in sensor pcb
GrundigCUC3400Poor purity & focus.C433 ( 1 , 000uf , 25v )
GrundigCUC3400No start up with tickingHT at chopper coll - C653 4n7 connected to pin 15 power chip u/s
GrundigCUC3400No start up - ticksC653 4n7 connected to pin 15 of power chip u/s
GrundigCUC3400No soundC266 1000µ 25v s/c; R367 8R2 safety res o/c
GrundigCUC3400No chan change when cold - display changes ok tho'Dry joint pin 15 tuner/if socket
GrundigCUC3400Int or perm tripping - ok on dummy loadTiming cap C653 4n7



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.