Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13483

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsMD1.1AColour spot during switch offReplace item R3392 on the CRT panel by a jumper. REMARKS :This modification was introduced in production from week 9727 onwards.
PhilipsMD1.1Dead with faint tripping heard with LED flashing red/orange/green every 2 secsI²C bus fault - SDA line held low; caused by the tuner
PhilipsMD1.1Bad focus or focus varies in a new set or after CRT replacementPossible solution: Short circuit the focus and the G2 pins of the picture tube with the aquadag coating. Switch the set on for approximately 5 seconds. After this return the set to its original condition. Check if the focus adjusted normally. If not repla
PhilipsMD1.0AREPAIR KITS AVAILABLEREPAIR KITS AVAILABLE In order to easily repair line and SMPS problems, two universal repairs kits are available for the following chassis: CHASSIS REGION MD1.0A 4:3 & 16:9 Asia Pacific & Latam MD1.1E 4:3 & 16:9 Eur
PhilipsMD1.0ANo synchronisation with OFF-AIR (arial) pictureCheck and replace if necessary: Item Description (New) Order number 2122 220nF 25V 20% 4822 126 13061 on the small signal panel. REMARKS :IRIS symptom code: F361
PhilipsMD1.0ANo synchronisation on AV (input) signalCheck and replace if necessary: Item Description (New) Order number 2115 220nF 25V 20% 4822 126 13061 on the small signal panel. REMARKS :IRIS symptom code: F361
PhilipsMD1.0ANo rasterCheck and replace if necessary: Item Description (New) Order number 2137 220nF 25V 20% 4822 126 13061 on the small signal panel. REMARKS :IRIS symptom code: 1316
PhilipsMD1.0AMicroprocessor Survey MD1.0AMicroprocessor Survey MD1.0A SOFTWARE FAMILY...VERSION...IDENT...SERVICE CODE...LAST VERSION Pal/Multi 4x3 4.4 3315 4822 900 14885 V4.6 (4.5..3353 4822 900 10968) (4.6...3448 4822 900 11073) NTSC Korea 4x3
PhilipsMD1.0AErrata MD1.0A AA Supplement (4822 727 21506)Errata MD1.0A AA Supplement (4822 727 21506) There is an error in diagram C on page 6. Position number 3376 (location L 10) should be 3380.
PhilipsMD1.0AEasy way to check the Power SupplyEasy way to check the Power Supply---------------------------------- The MC44603 can be checked for basic operation without the set being connected to the Mains supply. Method: 1) Discharge the 300V smoothing Capacitor. 2) Connect a BYD33D Diode to p
PhilipsMD1.0AClock inaccurateCheck and replace if necessary: item 1650 an improved 8MHz crystal (4822 242 10364). REMARKS :This solution is implemented in production from week 9727 onwards.
PhilipsMD1.0ABad focus or focus varies in a new set or after CRT replacementPossible solution: Short circuit the focus and the G2 pins of the picture tube with the aquadag coating. Switch the set on for approximately 5 seconds. After this return the set to its original condition. Check if the focus adjusted normally. If not repla
PhilipsLO1.1E/2EService mode enteringenter 062596 then OSD/STATUS button on handset. Arrow up/down to access req adj, arrow right/left to adjust, standby to store. Make sure chan 6 is tuned to a chan or test pattern as set ends up on chan 6.
PhilipsL9H.2E AACorrection to Service Manual L9H.2E AAIn the parts list of the service manual only the service code of the complete Clock Panel is mentioned. Below also the service codes of the separate components are listed. 1072 3119 108 51861 Clock panel complete (Small LED's) DP1 4822 265 30734 Co
PhilipsL9H.2E AAComPair/SearchmanIn the service manuals of above mentioned Chassis on page 14 paragraph 5.7 the ComPair tool is explained. However the ComPair/Searchman user software is not available.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads