Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | L6.1 | Does not find all programs during search. | Replace microprocessor IC7600 with version L6NOTXT-2.0, codenumber 4822 209 13085. | ||
Philips | L6.1 | Does not find all programs during search (for TXT and NO-TXT versions) | New software will solve this problem. Change software into new version;codenumbers are still identical 4822 209 14646:TXT 1 p Mono Pan-European L6TXTMOEU-1.1 3/4 keys:SAA5290ZP/072 4822 209 15425:TXT 1 p Mono Greek/Turkisch L6TMOGT-1.1 | ||
Philips | L6.1 | dead, LOPTr s/c | replace C2503 with 33nF 250V (532212142489), R3512 with 68k, D6510 with 12V zener | ||
Philips | L6.1 | Dead - chopper s/c, mains fuse o/c etc | Fit repair kit - still dead with squealing from tfmr - pin hole in BUT11AX encapsulation (measured ok out of cct) | ||
Philips | L6.1 | Cross picture (You can partly see the picture of the next station) | Add new Saw filter (CE marking module = 4822 212 11352). This filter can be switched between BG and DK. How to adapt the set: * remove saw filter on position 1001 and replace by CE marking module. * solder the black wire in the hole MCE1 near .P | ||
Philips | L6.1 | Cracks in sound during fast changing of picture from black to white. | New solution: Replace 9001 by 39 Ohm NFR = 4822 052 10399 and add 470 uF between 9001/3013 and ground (470 uF=4822 124 80791) | ||
Philips | L6.1 | Cracks in sound during fast changing of picture from black to white. | Change C2425 to 2200uF 25V.codenumber 4822 124 42449. REMARKS : This only occurs if contrast is at maximum. | ||
Philips | L6.1 | Colour flashes appears or loss of chroma in SECAM standard | Change R3433 (see Diagram A1) from 39K to 56K service code 4822 051 20563 | ||
Philips | L6.1 | Code-number supply-repair kit L6.1 | Code-number supply-repair kit L6.1 ---------------------------------- In the service manual of the L6.1 the codenumber of the supply-repair kit is missing. The code-number is 4822 310 10663. | ||
Philips | L6.1 | Bending picture depending on its white contents. | Change R3420 (see diagram A1) from 12k to 18K (service code 4822 116 52251) IRIS CODE : 1353 | ||
Philips | L6.1 | Bad focus or focus varies in a new set or after CRT replacement | Possible solution: Short circuit the focus and the G2 pins of the picture tube with the aquadag coating. Switch the set on for approximately 5 seconds. After this return the set to its original condition. Check if the focus adjusted normally. If not repla | ||
Philips | L6.1 | After a while white screen. | Check/replace LOT L5422. | ||
Philips | L6 series | Dead | Chopper FET, SOPS kit & HT smoother C2515 47µ 200v | ||
Philips | L2.2AA 29PT828C/05 | Dead - 5A fuse in plug o/c | Mains rect cap arcing 220µ 385v | ||
Philips | L01.2EE 21PT4457/05 | No red at sw on then reverts to st/by | R3316 68R 1/2w o/c, Tr7311 BF422 s/c b- e - on crt base |