Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | ANUBIS | SO FICA EM STAND BY (POWER OFF). | VERIFICAR CRISTAL 1630 DE 12mHZ. * JUL 95 ANC *. EPROM 7710. * OUT 95 ANC *. Receptor (1602). * 20Dez95 MJS *. | ||
Philips | ANUBIS | SINTONIZADOR COM POUCO GANHO | Capacitor com fuga 2265. * 04Jul96 JPBA *. | ||
Philips | ANUBIS | SINTONIA VARIANDO. | INTEGRADO 7225. * JUN 95 CTR *. | ||
Philips | ANUBIS | SEM TENSAO (VO, +B, HVT, ETC). | Nao ha +95V e +5V, possivel curto no ramal do +95V, verificar possivel fuga no flyback 5445. * 10Jan97 ANC *. | ||
Philips | ANUBIS | SEM SOM. (COM OU SEM IMAGEM P/ TV, VCR). | Integrado 7710. * SET 94 EGS *. Integrado 7225. * Nov 95 CTR *. Solda fria no SMD 3801 (2K), no decoder. * 06Fev96 ANC *. Verificar diodos 6809 e 6810 curto. * 25Ago97 JPBA *. | ||
Philips | ANUBIS | SEM SOM, POREM TEM RUIDO DE AMPLIFICACAO. | Verificar possivel fuga no transistor 7269. * 22Ago97 JPBA. | ||
Philips | ANUBIS | SEM SINTONIA. | Ver resistor 3648 (22k) e 3452 (47Û). * 02Out96 JPBA *. | ||
Philips | ANUBIS | SEM SINTONIA CANAIS ALTOS. | Aparelho com micro errado ANB4V1 no lugar ANBR500. * 05Jul96 JPBA *. | ||
Philips | ANUBIS | SEM SINCRONISMO VERTICAL (VERT5). | Verificar regulador 7218. * 10Out97 JPBA *. | ||
Philips | ANUBIS | SEM SINCRONISMO H/V. | DIODO 6441 EM CURTO. * DEZ 94 EGS *. Trilha aberta no JUMP 9694. * 10Jan96 ANC *. Integrado 7225 (TDA8361). * 11Jan96 ANC *. | ||
Philips | ANUBIS | SEM LINEARIDADE VERTICAL. | Resistor 3405 (47Û). * 02Out96 JPBA *. Verificar resistor 3404 (1K5) alterado. * 20Jun97 JDN *. | ||
Philips | ANUBIS | SEM CORES EM NTSC | VERIFICAR PROGRAMAÇAO. * JUL 95 CTR *. | ||
Philips | ANUBIS | RUIDO FORTE COM ANTENA (CHUVISCO) | Verificar capacitor 2265 pino 48 do TDA8361. 25Abr97 JPBA. | ||
Philips | ANUBIS | RUIDO DE ALTA (VAZAMENTO DE AT). | Capacitor 2530 (2K2) aberto. * 17Nov95 ANC *. | ||
Philips | ANUBIS | QUADRO PEQUENO | Integrado 7225 (TDA8361). * 12Fev96 ANC *. |