Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | ANUBIS | QUADRO DEFORMADO (SEM FORMA CORRETA). | UNIDADE DEFLETORA EM CURTO. * JUL 95 CTR *. | ||
Philips | ANUBIS | PERDE SINTONIA INTERMITENTE OU (LOOP). | CAPACITOR 2260 aberto ou bobina 5260 descalibrada. ** . IC 7225 (TDA8361), TAMBEM NAO ATUA AFT. * 13DEZ95 JPBA * | ||
Philips | ANUBIS | PERDE MEMORIA EM FUNCIONAMENTO. | APOS UMA PERDA DE BRILHO REPENTINA, VAI PARA CANAL INICIAL, VERIFICAR MICRO IC 7600. * MAR 95 CTR *. | ||
Philips | ANUBIS | NAO TEM CORES | EVITAR CABO DO YOKE PROXIMO AOS CRISTAIS. * NOV 95 JO *. Trilha aberta no JUMP 9694. * 10Jan96 ANC *. Integrado 7255 (TDA4461). * 11Jan96 ANC *. Integrado 7225 (TDA8361). * 12Fev96 ANC *. | ||
Philips | ANUBIS | NAO TEM CONTRASTE | Verificar resitor 3460 aberto. * 21Ago97 JPBA *. | ||
Philips | ANUBIS | NAO SAI DE STAND BY INTERMITENTE, OU NAO LIGA. | Verificar ajuste VO (95V), quando alto dispara o circuito de proteçao, ver resistor 3561 (56e). * 10Set96 ANC *. | ||
Philips | ANUBIS | NAO LIGA PELO CONTROLE REMOTO. | Diodo 6618 (BZX79 9V1) fuga, só ocorre com a tecla ON/OFF, pelos canais OK. * 26Fev96 HBG *. Ver 7636 (BC548). | ||
Philips | ANUBIS | NAO FUNCIONA (SO TELA COM CHUVISCOS). | CRISTAL 1630 (12mHz). * JUL 95 ANC *. | ||
Philips | ANUBIS | NAO FUNCIONA (FICA COMO DESLIGADO). | DIODO 6446 EM CURTO, (SAIDA H). * SET 94 EGS *. RESISTOR 3517, (3,3e), (fonte). * SET 94 EGS/CTR *. DIODO 6441 EM CURTO, (drive). * DEZ 94 JDCC *. VERIFICAR ESTAGIO VERTICAL (1449/7400/6416/2414/MCSS) CASO ESTEJA FECHADO, PROVOCA A PERDA DE C | ||
Philips | ANUBIS | NAO APARECE CARACTERES / MENU. | Verificar transistor 7635 (BC548B) com fuga. * 03Mar97 ANC* TS7634, S5720, C2721, C2722, IC7600, 7225 e Sand Castle. *18Set98 H.desk* | ||
Philips | ANUBIS | NAO ABRE VERTICAL | CAPACITOR 2415 ABERTO. * JUL 95 JDCC *. Capacitor 2404. * 29Ago96 JPBA*. Resistor 3403 (2k7) aberto. *02Out96 JPBA *. C2426, 2427, 2414, D6416, 6449, 1449, IC400, 7225, fonte de +26. | ||
Philips | ANUBIS | LINHAS DE RETORNO (RETRAÇO). | 7400 DANIFICADO POR PROVAVEL AUMENTO DA FONTE | ||
Philips | ANUBIS | LINHA FINA NO CENTRO (HORIZONTAL). | Solda fria no resistor 3448 (330E). * Nov 95 ANC *. | ||
Philips | ANUBIS | LED STAND BY NAO APAGA.(APARELHO EM ON) | VERIFICAR MICRO IC 7600 NA POSIÇAO DE SERVIÇO, QUANDO EM FUNCIONAMENTO PODE PISCAR DUAS VEZES E ATUAR COM CONTROLE OU PISCAR 5 VEZES E NAO OPERAR COM CONTROLE. * ANC *. | ||
Philips | ANUBIS | LED INTERMITENTE (ALEATORIO). | 1 PISCADA PROBLEMA NA RAM (MICRO) 2 PISCADAS LINHA DE DATA E CLOCK 3 PISCADAS EEPROM 4 PISCADAS PLL DO TUNER (VARICAP) 5 PISCADAS PROBLEMA DE LEITURA APOS ESCRITA (VER PROGRAMAÇAO/EEPROM) 6 PISCADAS |