Dicas Reparação Panasonic





Pesquisa: Panasonic

Resultados 2657

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PanasonicZ3TFIELD CRAMPING WHEN COLDTDA3653C IC451
PanasonicZ3TField collapse & lin intDry joints TDA4505 IF/timebase chip under metal can
PanasonicZ3TDead with squealLOPTr 2SD1439 leaky - used BU508D - resold Line dr tfmr T531
PanasonicZ3TDead - st/by onlyNo HT - STR54041 faulty
PanasonicZ3TBrightness correct top left out bottom right.Q306 collector-to-emitter leak.
PanasonicZ3 ChassisTuning driftsC17 10nF ceramic cap leaky
PanasonicZ3 ChassisTrips at sw onCheck start up resistors R560 270k & R552 27k for hi res
PanasonicZ3 ChassisSt/by onlyIC1101 micro pin 6 should be high (power on command) but wasn't as chip not being reset. IC1104 resets IC1101 when its supply reaches 5v but didn't reach this level as zener D810 in the 5v reg cct was leaky
PanasonicZ3 ChassisReverts to st/by with rush of EHTHT correct - no line drive; removing prot tr Q451 revealed field collapse caused by D453 MA2270 zener diode - the cause of this fault was traced to flashover in crt
PanasonicZ3 ChassisNo start up Works ok when pin15 (X ray prot) IC101 is grounded; R560 270k near plug E7 o/c
PanasonicZ3 ChassisNo colorC616 10nF 50v leaky - pin 29 IC101
PanasonicZ3 ChassisInt picHairline cracks around line dr trfmr T531
PanasonicZ3 ChassisInt dead IC1101 reset line slightly low ; C1122 0µ01 leaky
PanasonicZ3 ChassisField scan cramped at bottom at sw on IC451 TDA3653C FOP chip
PanasonicZ3 ChassisField lin - top stretched & bottom compressedC458 4µ7 or 10µ 50v



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads