PanasonicZ3 ChassisField - reduced height with poor linC404 4µ7 50v
PanasonicZ3 ChassisFailure to startR802 330k o/c - bias provider for chopper chip
PanasonicZ3 ChassisFailed to start - int, with no R/C operation5v supply from small trfmr at TPE2 = 4.4v; D1124 5v1 zener leaky
PanasonicZ3 ChassisDead - no volts from psuRemove Q806 st/by tr & wind up mains via variac; all worked ok & Q806 2SA683 was faulty
PanasonicZ3 ChassisDeadR801 4R7 5w o/c, IC801 STR50103A-M s/c, D816 HT SR2KN prot diode s/c, Q806 St/by sw tr 2SA683 s/c,, R559 10R 7w o/c, Q551 2SD1439 LOP Tr leaky
PanasonicZ3 ChassisCuts out on bright scenesR316 47k in beam lim cct o/c
PanasonicZ3 ChassisColour at max & won't reduce - OSD does alterIC1101 micro pin 31 doesn't vary when col adj. Control carried out in IC101 pin 21 on if/dec panel; when this pin grounded a mono pic observed; D1149 MA165 diode leaky
PanasonicZ3XRAY PROT WORKINGCHECK R560 270k
PanasonicZ3Tuning drifting - worse from cold.C17 ( 10nf ) leaky.
PanasonicZ3Trips off aft 2 secsR560 270k in trip cct (185v supply to RGB monitor)
PanasonicZ3TRIPS OFFR560 270k R552 27k
PanasonicZ3STUCK IN STBY IC1104 5v RAIL LOW AT 4vQ804 OR ZENER DIODE D810
PanasonicZ3Set buzzes from PSU but deadIf pin 15 IC101 high ( X-ray protection ) try shorting to chassis , if set ok check Q502 and R560 270k
PanasonicZ3Reduced height poor linearityC404 ( 4u7 ) 50V
PanasonicZ3POWERS UP THEN GOES DEADREMOVE Q451 POWER UP ON VARIAC , IF FIELD COLLAPSE CHECK D4539 ON ODD OCCASIONS FLASHOVERS IN TUBE CAUSE DIODE TO FAIL



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.