SintomaCausaSoluçãoPor:
PanasonicTX25MD4reverts to st/by aft few secsDry joints around FOP chip IV451 (could only be seen with magnifier)
PanasonicTX25MD3 Euro2MNo sound or vis. Stby LED on & "flicking" approx every sec. Relay not triggering. Set works ok if relay is bypassed & set taken out of stbyReplace leaky diode D814 (1SS133T-77) mounted across the relay coil.
PANASONICTX25MD3SOUND BUT NO PICTURECHECK R507 3.3 OHM
PanasonicTX25MD3No start up until warm2 x 100µ caps in PSU pri
PanasonicTX25MD3GHOST IMAGE ON SCREENDISCONNECT SCART LEADS
PanasonicTX25MD3Field scan flshes & no sound when coldIC601 VDP3108APPA1 vid proc chip - kit pt no TZS9EK002-2 which includes EEPROM - only fit EEPROM if orig chip type = VDP3108-29
PanasonicTX25MD1/MLine twitch - like loss of syncReplace IC601 @ £27 + vat
PanasonicTX25MD1Sound distorted & lowIC2101 MSP3410-15 64 pin device - don't order from SALI cd -wrong
PanasonicTX25MD1RGB LINES AT TOP OF SCREENREPLACE D454 AND D456
PanasonicTX25MD1GREEN SPECKLES ON RF AND SCARTREPLACE IC601
PanasonicTX25MD1Field - 2 flashing col lines across centre of screen & lin problems on some picsreplace TDA8175 with pana spec type and check/replace D456 16v zener (MA2160B) s/c & change C456 (220uF 50v)
PanasonicTX25MD1DEAD FUSE BLOWNREPLACE POSISTOR R808
PanasonicTX25MD1DeadTDA8175 field ic faulty & D456 MA2160 zener s/c
PanasonicTX25D1/BHSt/by onlyTDA8175 fop chip (with "3" prefix), 1.25A wickman fuse off chopper tfmr o/c, D456 zener 16v MAZ160 s/c & check R472 4R7 hi res & 220µ 50v cap
PanasonicTX25AD2DP Euro 2Line jitter - intFit mod kit TXS9EK002-2; but do not replace EEPROM on this model or sound will be lost (Pro Logic version)



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.