Dicas Reparação SAMSUNG





Pesquisa: SAMSUNG

Resultados 3888

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SamsungTVP5050Reverts to st/by aft pic displayed for a few secsLighthouse LED not working - faulty
SamsungTVP33601Field foldover at topCheck R409 0R22, R303 10R ½w from 46v supply
SamsungTVP3350ITnot recording sound on timer recordingsreplace micro IC901 CXP85332A1966 and set option codes for this model: option 1 193, option 2 32
SamsungTVP3350ISt/by onlyNo volts to IC901 pin 64, D901 IN4148 Leaky
SamsungTVP33501TNO TEXTENTER SERVICE MODE AND ENTER 209 IN OPTION 1 AND 34 IN OPTION 2
SamsungTVP33501SInt off & long time to come on from mains sw onIC801 opto coupler
SamsungTVP33501No signalsCheck dry joints tuner around coils & Xtal etc
SamsungTI20C5DF2S/XEVDead except for cycling on/off of degaus relayC414 680pf 2kv burnt & leaky in lop stage
SamsungTI20C5DF2S/XEVDead except for cycling on/off of degaus relayC414 680pf 2kv burnt & leaky in lop stage
SamsungTI14C5DeadOpto coupler
SamsungTI 20C5DF2STries to start up with relay clicking then shuts down - vcr sect okTDA8356 field IC & R303 10R
SamsungT1-20C5DFDeadReplace RA802 330K in primary
SamsungSCT12B CI5944Nframe foldover at the topR307 10R 0.5W o/c
SamsungSCT12Bno power up LED flashes yellowcheck IC901 has 5v supply, osc at pin 31,32 - if no osc sus xtal X901
SamsungSCT12BFlyback line at top of screenR307 10R



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.