Dicas Reparação SAMSUNG





Pesquisa: SAMSUNG

Resultados 3888

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SamsungCI5913WNo pic - sound okWhen A1 advanced dim, wide pic seen. HT correct but had noise superimposed on it. C41 4µ7 400v u/s
SamsungCI5913WExcess width & no E-W corrC416 2µ2 250v in anti breathing cct
SamsungCI5913 U88HIGH FREQUENCY VIBRATION NOISE FBT VIBRATION , ANDREPLACE FBT ( 3 HOLE FIXING TYPE ) , BOND R414 ,
SamsungCI5913 CI6813 U88FAILURE OF C560 ( 2.2mfd / 250v ) CRT BASE.REPLACE C410 TO NEW TYPE AND CAY OUT MOD
SamsungCI5913 & CI6813If HT smoother C560 2µ 250v has failed (on CRT base)Change C410 or C401 from 220µ 100v to 47µ 250v. Connect -ve pin to chassis. Change C416 from 2µ2 250v to 47µ 250v. If R415 0R27 ½w is fitted check for o/c - if so replace - official Samsung mod
SamsungCI5913 CI6813 U U88DARK PICTURECHECK C416 ( 155v SMOOTHING ) REPLACE WITH 47mfd 250v
SamsungCI591Dark pic with ringingCaps in 175v supply to RGB low - C560 2µ2 400v on crt base & C410 220µ 200v on main pcb
SamsungCI541ZGWill not lock into channels - no sound.B5 rail @ 3.4v Infra red Rx leaky ( unplug PA01 - 5 rail restored )
SamsungCI541ZGStuck in standby.Q402 ( 2SD1650 ) s/c.
SamsungCI541ZGSound crackling & cutting out.R618 ( 5.6k ) near audio IC.
SamsungCI541ZGPSU & LOPT pulsing - no sound.B5 rail @ 3.4v Infra red Rx leaky ( unplug PA01 - 5 rail restored )
SamsungCI541ZGNo sound - set tripping - black bars on pic.B5 rail @ 3.4v Infra red Rx leaky ( unplug PA01 - 5 rail restored )
SamsungCI541ZGNo red may be int.Drys Q556 ( CRT PCB )
SamsungCI541ZGInt shut downInvisible dry joints at chopper trfmr
SamsungCI541ZGFrame collapse.R412 ( 1R 1/2w fusible ) o/c.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.