SintomaCausaSoluçãoPor:
SamsungC1537VFAILURE OF Q901 2SC3552 AT SWITCH ONREPLACE R910 270k
SamsungC15012ZDRIFTS OFF TUNER116 ( 120K )
SamsungC13312ZVOLUME STUCK ( MAX ) OSD DOES CHANGER625 ( 10K ) OPEN
SamsungC13312ZNO TUNING 0-30V LINE NOT VARYING05 ( 10K ) OPEN
SamsungC1210RSt/by only 11v HT line rises to 2.5v then off. D106 FR304 efficiency diode in LOP stage s/c
SamsungC1210RBlank white raster with fb linesCRT cath volts low due to C512 22µ 160v in 115v supply dried up
SamsungC!3312ZField collapseR307 33k hi res
SamsungBT309KBlank white raster.Detector can in IF strip.
SamsungBT309KBlank white rasterDetector can in IF replaced
SamsungBT110Servicing the Samsung Model BT110See TV Mag Aug 1993
SamsungBT110No tuningR128 6k8 feed res to 33v reg o/c
Samsung5052X P64Raster blanked offNo Y signal out of jungle chip to timebase - R420 22k feeding line pulses to jungle chip o/c
Samsung3373ZOff with a BANGC805 2200pf 800v leaky - had shattered fuse and caused blackening of pcb - under psu reg heatsink
SamsungDT15LS7L / DT15VSPN - 550S / 5Distorção da imagemSubstituir: R415 De : 12R para 15R
SamsungDP15LS7L / 550SSem vídeo e led piscando. Substituir: C417 De :100nF 50V C por 470nF 63V MP



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads