SonyFH50WXWIRING HARNESS Need part number for FH-33 wiring harness if possible.Suspect this is a European model. -HQ COMMENTS: You are correct the FH-33 is a European model. The partnumber for the wiring harness is 1-558-567-11. This is the same harnessas used in the FH-50WX.
SonySTRAV780NO SOUND ON LEFT CHANNEL Sound was coming out on right side only and the displayindication was all the way to the right. Data from the key matrixcontroller was reaching the main controller, but the main controller wasnot sending data to ASP chip. Replaced IC-251. -HQ COMMENTS
SonySLV70HFTRACKING METER BAR DOES NOT APPEAR ON THE SCREEN When playing back a tape, the tracing meter bar does notappear on the screen. -HQ COMMENTS: The tracking meter bar only appears on the screen when therecording is in Hi-Fi. It only appears for a few seconds and thendisappears if tracking adjustments ar
SonyCFS20SERVICE MANUAL AVAILABILITY Is CFS-20 a U.S. model and is a service manual available? -HQ COMMENTS: This is a 1981 Japanese model. We have a service manualthat you may borrow.
SonyCCDF40ROLLING OF TIME AND DATE Slow, intermittent roll, top to bottom of time and date. Noroll in picture. Roll is recorded on tape.
SonyXR7180UNIT DAMAGED DURING SERVICING Pins 7 and 10 on (Main) board are not connected to ground viapin 4 of CNP-909. There may be a break in the trace, but the technicianhas not been able to locate it.
SonySTRAV1010NO VOLUME IN SURROUND SPEAKERS Actually, when stereo signal applied to CD or other inputs,surround speakers worked. FM not going into stereo mode. Mono FM causedno sound in surround speakers on all modes except simulated. FM mono dis-tortion level very high.
SonyCCDV5NO VIDEO No video when playing VCR, the characters in the EVF wererolling, i.e., no vertical sync. Reference V signal was present at inputof (VC-10) board, pin 15, but not at output, pin 7, (VC-10) board. If Ipassed my hand over IC-003, the display would try to
SonySL2005NO OPERATION WITH BATTERY Unit would not work with battery but worked ok with AC input.When battery was installed, DC line measured 12 volts but quickly droppedto 1VDC when ON/OFF switch was pushed on. The set worked ok with batteryholder disconnected and external DC applied to
SonySTRAV300UNIT TURNS ON WHEN PLUGGED IN/MISSING GROUND JUMPER WIRE 1. Unit will turn on when plugged in even though it was un-plugged while off. 2. Unit goes into protection.
SonySLV757UCCHECKING TIMER SETTINGS We do not have an operation manual. How does the customercheck this timer - activated recording settings: -HQ COMMENTS: Please have customer check page 49 of the owners manual.
SonyAC40AAC-40A AC ADAPTOR IS NO LONGER AVAILABLE The AC adaptor, AC-40A, is no longer available. This adaptorwas 6V at 800mA. What is a suitable replacement AC adaptor? -HQ COMMENTS: Please use the AC-D468 as a replacement. The AC-D468 isswitchable 6, 9, 12V at up to 800mA.
SonyFD40AAC-40A AC ADAPTOR IS NO LONGER AVAILABLE, USE AC-D468 The AC adaptor, AC-40A, is no longer available. This adaptorwas 6V at 800mA. What is a suitable replacement AC adaptor? -HQ COMMENTS: Please use the AC-D468 as a replacement. The AC-D468 isswitchable 6, 9, 12V at up to 800mA.
SonyCCDV220VIDEO EDIT There seems to be some confusion with our dealers on whetherthis unit does a video insert without erasing the PCM track. -HQ COMMENTS: No, an audio dub may be done after recording video, but avideo dub is not possible.
SonyKPR4620NO DC VOLTAGES LISTED ON (C) MOUNTED BOARDS, VOLTAGES BELOW Service manual does not show any voltages for CRT sockets.What should voltage be? a K b G1 - Grid c G2 - Screen d G4 - Focus -HQ COMMENTS: We are checking the voltages with our lab



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.