SonyKV32SXR10TIME CLOCK TOO FAST, SEE S/B 87R1, ADD CAPACITOR The time clock advances 12 minutes every hour. This indicatesthe microprocessor IC-101 is set to 50Hz. -HQ COMMENTS: Please refer to Service Bulletin number 87R1.
SonyKV27HSR10CLOCK RUNS TOO FAST, SEE SERVICE BULLETIN 87R1 The time clock advances 12 minutes every hour. This indicatesthe microprocessor IC-101 is set to 50Hz. -HQ COMMENTS: This problem is caused by 50/60Hz misdetection. Please refer to Service Bulletin number 87R1. Add .01uf50v cap betweenBase and Emitter
SonySLHF600REPLACEMENT VIDEO HEADS Regarding bulletin 149R, original P/N A-6762-177-A changed toA-6762-178-A now is being substituted w/ A-6762-227-A. Original headchipped while cleaning but still working ok. When -227-A installed, RFenvelope dropped from approx. 1200mV to approx. 700mV
SonySTRAV900NO STATION MEMORY Unit had other problems Dsply bd. was replaced w/ new bd.Unit did not retain memory - when unit was turned on or off, a flashing/blinking dsply would occur. On battery voltage to memory, saw when pwrwas rmovd from unit, memory battery voltage drops to
SonyLCV814PART NUMBER FOR STRAP I need a part number for the strap on the case. -HQ COMMENTS: Please try 3-712-595-11. It is the camera strap partnumber.
SonyCCDF40REPLACEMENT EVF NOT THE SAME AS SERVICE MANUAL The replacement EVF is not the same as the one in the unit. -HQ COMMENTS: Please refer to CCD-F40 service manual - supplement No. 2.
SonyTCD5MSERVICE MANUAL IS NO LONGER AVAILABLE The service manual for this unit is no longer available. Thisunit was introduced in 1986 but is still for sale in SONAM. Can you makethis manual available again or should we just have Kansas City Parts makecopies to sell to customers? -HQ COMMENTS: I
SonyD9PART NUMBER FOR WORM GEAR IS NOT LISTED The part number for the worm gear is not listed in theservice manual. In fact the part is marked as not supplied. Can we get apart number? -HQ COMMENTS: This part will not be available separately. It issupplied with the MD chassis assembly.
SonyKV27TX20NO SYNC ON CHILD PICTURE, TROUBLESHOOTING SUGGESTION Main picture ok - child picture is out of horizontal sync. -HQ COMMENTS: Check sync component pin 2 IC-1303 and check sync inputpin 36 IC1101. Also check pin 47 frequency 14.3MHz and pin 53 14.3MHz.Pin 60 and 59 are the sync outputs IC-1101. Technicia
SonyCCDF35WAVY LINES IN PICTURE Wavy lines all the way through the picture. -HQ COMMENTS: May be caused by wind getting into the cassette compart-ment.
SonyCCDF36WAVY LINES IN PICTURE Wavy lines all the way through the picture. -HQ COMMENTS: May be caused by wind getting into the cassette compart-ment.
SonyFD500NEED PART NUMBER FOR WHITE CABINET No part number for white cabinet found in service manual. -HQ COMMENTS: The part numbers are as follows: Front cabinet part numberis 3-345-525-31, rear cabinet part number is 3-345-526-31.
SonyD15INTERMITTENT NO FOCUS OR NO FOCUS (NO PLAY/START) The focus bias is off because clearance between the turntableand MD chassis is too low. It should be 2mm. It is around 1.5mm. Turn-table gradually lowers with use causing the focusing distance to change.
SonyCCDF36NO EJECT No eject. Unit attempts to eject then shuts down. Turn take-up reel during eject cycle then eject function ok. Found defectivecapstan motor. -HQ COMMENTS: The capstan motor also drives the reel mechanism so ifthe reel does not rotate in the eject mod
SonyCCDM8UBATTERY LIGHT BLINKS - NO FUNCTIONS Unit is dead except for flashing battery lamp.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.