Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | TCW530 | RECORD | Record level could not set. Everything else OK. | ||
Sony | HVA220 | P/N FOR CAMERA CONNECTOR | Need part number of male camera connector that plugs into14 pin input connector on HVA-220. -HQ COMMENTS: Please use the following P/N14 pin connector male : 1-560-110-00 female : 1-560-134-00Pins for connector male : AWG24-20 1-56 | ||
Sony | SL5600 | NEED P/N FOR CASSETTE COMPARTMENT BRACKET | Need to order part directly below Ref # 57 (Pg 4-2 of S/M)to which spring #56 hooks into. Please advise. -HQ COMMENTS: This part is unavailable. Please replace the entirecassette-up block assy (A-6751-061-A). | ||
Sony | CCDM8U | P/N FOR LOWER CABINET ASSY | Refer to Supplement-2 of S/M. I need the lower cabinet assy.Please inform P/N. -HQ COMMENTS: This part is unavailable since it contains so manyindividual parts. Please order the complete grip block assy (Ref. No. 5P/N A-7080-063-A). | ||
Sony | SLHFR70 | VIDEO NOISE IN CUE/REVIEW | Excessive video noise in CUE/REVIEW. P/B OK. | ||
Sony | PSX600 | HIGH PITCHED SQUEAL | High pitched squeal from output when arm moves laterally. Ifarm is damped by hand, oscillation disappears. | ||
Sony | KV1922 | TUNING DRIFTS | Tuning drifts. No problem if substitute VC supplied from10VZ source. | ||
Sony | STRV55 | HUM IN BOTH CHANNELS LOW VOLUME IN LEFT | The unit had a hum in both channels that would disappear assoon as a scope probe ground connection was made. Also there was lowvolume on the left channel - all modes. We found the problem to becaused by crystaline growth on IC601 and C603. We cleaned | ||
Sony | CCDV110 | PICTURE FLUTTER UNDER CERTAIN LIGHTING | The VTR works fine. However, when the camera has the upper1/3 in bright light and the lower 2/3 is relatively dark there is anoticeable flutter in the playback picture. This is not seen in the EVF.We have gone through the iris and agc adjustments with | ||
Sony | G1500 | TURNTABLE DOES NOT WORK - ARM WILL NOT CYCLE | Arm will not cycle on turn table.Arm slide (Ref. 473) pin jumps out of cam gear (Ref. 460) track. | ||
Sony | G1500 | TAPE DECK INOPERATIVE | Roller pops out of the pinch roller assembly. | ||
Sony | KPR4620 | INVERTED IMAGE, SEE SERVICE BULLETIN # 302 | Customer complained about an inverted image on bottom lefthand side. This is only noticed when the room is very dark and thepicture has a dark screen. | ||
Sony | CDP701ES | NOISE DURING SCAN | Clicking noise is heard when scanning to the next selection.All power supply filter capacitors have been changed, also the regulatorICs (+/-12V, +/-5V). No change. Found out that this noise did not appearuntil the STK6922 were replaced with BX1201. | ||
Sony | KV25XBR | VERTICAL JITTER | Vertical jitter on satellite and prerecorded copy guardedtapes. | ||
Sony | CCDV110 | SCRAMBLED IMAGE | This unit had a scrambled image in the view finder andrecorded on the tape. It appeared as though, the horizontal was offfrequency, because of the horizontal lines in the picture. |