Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsKT3Dead.4.7R w/w R6191 may be shown as R6291
PhilipsKT3CRT down.For tube boost s/c 1 of the chokes L9603/9604 Note only do 1.
PhilipsKT3Continous tripDry joints C567 (below LOPTx)
PhilipsKT3col fades out after 2 hrsC56 0.1µ connected to pin 23 TDA3560 faulty
PhilipsKT3Channel change - intermittent.IC70 ( 4074 )
PhilipsKT3Brightness - intermittent.Drys on plug by high wattage res on remote PCB.
PhilipsKT3Blank raster.IC TDA2571 sync/line IC.
PhilipsKT3Blank raster with flyback lines.R587 ( 100R ) by drive pre-sets change in value 160v feed to RGB
PhilipsKT3Blank raster with flyback linesR455 SC 560R 1W.
PhilipsKT3155v rail low.DJ on R1583 ( 2R2 )
PhilipsK40WHISTLINGBU508 SHORT CHECK IC7120 OPTO ( CNX62 )
PhilipsK40VERY FAINT RASTERCHECK THE TDA3561 COLOUR IC
PhilipsK40Txt lines showing at top of picC2107 100µ 50v
PhilipsK40Txt lines at top of picC2107 100µ
PhilipsK40Striations on left-hand side.Check R3191 for o/c.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads