SonyCCDTR5DOOR WILL NOT CLOSE The TP arm block assembly (page 215, reference number 175) hadcome out of unit. The T protector assembly was bent. Replaced theseparts (including washers and joint bar). Unit would close and start toload. Then unit would jam due to misalignment of TP
SonyICF2010INCORRECT SCAN After entering the lower and upper scan limit frequencies in,the unit would not scan correctly after pressing the scan start button.This also pertains to serial numbers 302902, 302903 and 303001.
SonySTRGX6ESIIINSULATING MICA PART NUMBER I need the part number for the insulating mica for the outputtransistors (2SC2921/2SA1215). Not listed in two page service manual forthis model and different than those used in GX6ES. Because of the largesurface area and suction of heat-sink compound,
SonyD160REPLACEMENT OPTICAL BLOCKS Replacement blocks coming through with pin 3 and 4 solderedtogether on 12 pin flex connector. This is just a little drop of solderwhich can easily be overlooked and cause the block not to work wheninstalled. This also is true on other models.
SonyD180REPLACEMENT OPTICAL BLOCKS Replacement blocks coming through with pin 3 and 4 solderedtogether on 12 pin flex connector. This is just a little drop of solderwhich can easily be overlooked and cause the block not to work wheninstalled. This also is true on other models.
SonyD9REPLACEMENT OPTICAL BLOCKS Replacement blocks coming through with pin 3 and 4 solderedtogether on 12 pin flex connector. This is just a little drop of solderwhich can easily be overlooked and cause the block not to work wheninstalled. This also is true on other models.
SonyD4REPLACEMENT OPTICAL BLOCKS Replacement blocks coming through with pin 3 and 4 solderedtogether on 12 pin flex connector. This is just a little drop of solderwhich can easily be overlooked and cause the block not to work wheninstalled. This also is true on other models.
SonyD2REPLACEMENT OPTICAL BLOCKS Replacement blocks coming through with pin 3 and 4 solderedtogether on 12 pin flex connector. This is just a little drop of solderwhich can easily be overlooked and cause the block not to work wheninstalled. This also is true on other models.
SonyCDXR79REPLACEMENT OPTICAL BLOCKS Replacement blocks coming through with pin 3 and 4 solderedtogether on 12 pin flex connector. This is just a little drop of solderwhich can easily be overlooked and cause the block not to work wheninstalled. This also is true on other models.
SonyCFS902PART NUMBER LISTED FOR S302 IS WRONG Part number 1-570-347-31 is a two-position switch. This isthe wrong switch. It needs to be a three-position switch.
SonyCFS903PART NUMBER LISTED FOR S302 IS WRONG Part number 1-570-347-31 is a two-position switch. This isthe wrong switch. It needs to be a three-position switch.
SonyKV13TR10CRT CRT in unit has the CRT, coil (degauss) and metal shield asone complete unit. Replacement CRT comes just with the CRT. We need thecomplete assembly part number. -HQ COMMENTS: There are two types of CRTs being used - one is in theservice manual. The o
SonyKPR41DS1SPOTS ON SCREEN,DUST BETWEEN SCREENS CLEANED There were spots on the screen, one big one toward the bottomright hand portion of the screen. Took screens apart and found fine dustparticles. With a fine brush I was able to clean both screens. With thescreens rubbing together in shipping, there mus
SonyKPR41DS2SPOTS ON SCREEN, SEE TV SERVICE BULLETIN # 17 There were spots on the screen, one big one toward the bottomright hand portion of the screen. Took screens apart and found fine dustparticles. With a fine brush I was able to clean both screens. With thescreens rubbing together in shipping, there mus
SonySTRAV910WRONG PART NUMBER FOR 6 PIN OUTPUT JACKS J403-J405 The part number listed in the manual for the output jacks areall the same regardless if it is a 4 pin or 6 pin jack.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.