SonyTAM30UNIT CUTS OFF DURING OGM PLAYBACK TO THE CALLER When incoming call is received, OGM is activated, but is pre-maturely cut off. This is due to the fact that pin 52 of IC-3 has to beheld low while the OGM is played to the incoming caller. In order forthis to be accomplished, Q-4 must be turned on by Q
SonyTAM50CONTINUOUS LINE CONNECT WITH POWER APPLIED TAM seizes telephone line when power is applied. Pin 25 ofIC-3 (line on pin) is being held high, which turns on Q-2 and Q-1,which causes the line to be seized. Pin 25 is getting the high from R-241on the (sub board), but R-241, R-242 and Q-207 all che
SonyXR170RADIO SECTION INOPERATIVE AFTER EJECTING CASSETTE The above problem may occur due to a slight misadjustment ofthe small tab on the eject cam lock assy. After ejecting the tape, themisadjustment of the tab allows the carriage assy to drop back down intothe tape-loaded position, which sets S903 (radio/ta
SonyESR6RADIO SECTION INOPERATIVE AFTER EJECTING CASSETTE The above symptom may occur due to a slight misadjustment ofthe small tab on the eject cam lock assy. After ejecting a tape, themisadjustment of the tab allows the carriage assy to drop back down intothe tape-loaded position, which sets S903 (radio/tape
SonyXR4057RADIO SECTION INOPERATIVE AFTER EJECTING CASSETTE The above symptom may occur due to a slight misadjustment ofthe small tab on the eject cam lock assy. After ejecting a tape, themisadjustment of the tab allows the carriage assy to drop back down intothe tape-loaded position, which sets S903 (radio/tape
SonyESR400RADIO SECTION INOPERATIVE AFTER EJECTING CASSETTE The above symptom may occur due to a slight misadjustment ofthe small tab on the eject cam lock assy. After ejcting a tape, themisadjustment of the tab allows the carriage assy to drop back down intothe tape-loaded position, which sets S903 (radio/tape
SonySPP320DIFFERENT MAIN BOARD IN UNIT Request updated information or supplement manual on Base MainBoard which has part number 1-634-940-11 marked on the board. The mainboard that matches the current schematic and is in current SPP telephonesare marked 1-632-800-12. -HQ COMMENTS: To Tokyo:
SonySPP90NO POWER IN BASE OF UNIT No power in base of SPP-90. Connection between D-301 and R-401is broken loose. Some were never soldered and some just break loose.
SonyTAM50BEEP TONES DURING MEMO OR CONVERSATION RECORD Constant or pulsing beep tones during Memo Record andConversation Record.
SonyTAM30BEEP TONES DURING MEMO OR CONVERSATION RECORD Constant or pulsing beep tones during Memo Record andConversation Record. Also applies to serial numbers 12121, 15230 and27297.
SonyTCFX510INCORRECT PART SUBSTITUTION - CAPSTAN MOTOR When the above P/N is ordered, it subs to P/N 1-541-745-11.This motor is an EG-530AD2B. It physically fits in the unit with noproblem it is physically the same. However, the motor runs too fast,even with the speed control adjusted to minimum. Is there
SonyKV27HSR10NO HORIZONTAL PINCUSHION CORRECTION, CRACK NEAR FBT/PIN 11 Pincushion adjustment inoperative L-501, R-571, Q-505, etc.checked ok. DC voltages on IC-531 ok. Replacement of IC-531 did notchange condition.
SonyFD250STATIC THROUGH ALL STATIONS, OPEN FOIL It won't tune to any station, only snow.
SonyKV32XBR50H-STAT CONVERGENCE PROBLEM, REPLACED CRT After about three minutes of operation, horizontal static con-vergence shifts out gradually.
SonyKV1943RIMMEDIATE SHUT DOWN, REPLACED C-539 Unit came in dead. After replacing shorted Q-901, Q-902 andopen F-603 regulated +115VDC read about 130VDC. Replacement of IC-601didn't help. Scoping TP-91 for ripple found about 4VPP horizontal rate.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.