Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CDP37 | RF PLL ADJUSTMENT PROCEDURE STEPS 1 AND 2 ARE INCORRECT | RF PLL adjustment procedure steps 1 and 2 are incorrectlystated. | ||
Sony | XR7150 | HAS NO MEMORY AFTER REMOVED FROM POWER SOURCE | When unit is removed from power source and then reinstalled,it had no memory. Found an open Q-311 was causing problem. | ||
Sony | CDP31 | RF PLL ADJUSTMENT PROCEDURE STEPS 1 AND 2 ARE INCORRECT | RF PLL adjustment procedure steps 1 and 2 are incorrectlystated. | ||
Sony | CDP27 | RF PLL ADJUSTMENT PROCEDURE STEPS 1 AND 2 ARE INCORRECT | RF PLL adjustment procedure steps 1 and 2 are incorrectlystated. | ||
Sony | STRGX60ES | BROKEN POWER SUPPLY BOARD - DEAD UNIT | This is the third unit I have seen with damage to the powersupply board. All three were dead out of the box. The cracks are locatednear transformer T-901. It appears that T-901 is just heavy enough tooverstress the board should the unit be dropped in | ||
Sony | TCRX50ES | IRREGULAR MECHANICAL MOTION | Unit will go to Fast Forward or between FF and Stop when Playis pressed. Cam gear (162 pg. 18) will rotate and solenoid will operate,but unit will not lock into Play even though Play is indicated by functionlights. Have seen this problem on three units | ||
Sony | KV27EXR15 | BUZZING SOUND, REMOVED SHIELD ON T-602 | Buzzing noise coming from the set. Replaced T-602 stillbuzzes. Used RTV on the metal shield of T-602 - still buzzes. Removedmetal shield and customer is satisfied. -HQ COMMENTS: We will send your report to Tokyo. Please continue toreport to us infor | ||
Sony | KV32XBR15 | NO VERTICAL SWEEP MICRO LOCKED UP, P-14/PIN 1&2 SOLDER SHORT | No vertical sweep or any control over functions. There was novertical drive, pin 31, IC-301. The DC voltages on data and clock lines,pins 47 and 48, IC-301, were present. Date and clock pulses were alsopresent. A resistance check between pins 47 and | ||
Sony | FD500 | NO PICTURE; H FREQUENCY TOO HIGH, RESOLDERED C508 | No picture - low horizontal output signal pp value.Horizontal frequency has increased in this case to about 68kHz. Frequencyis still adjustable by RV-501. All DC voltages on IC-201 are ok. After ashort period of time, the horizontal output becomes ext | ||
Sony | TCFX110 | MECHANISM IS DIFFERENT FROM WHAT IS SHOWN IN MANUAL | There are some differences in the mechanism when compared tothe exploded views in the S/M. A pinch roller was ordered and it did notfit. -HQ COMMENTS: There are 2 different mechanisms used in the TC-FX110.The early units have mecha type TCM-YM47CW-62, | ||
Sony | CDPC900 | DIRTY FOP LENS CAUSING SKIPPING | In this particular unit the complaint was continuousshuffling. Unit could not lock on to discs in the shuffle mode. Theoptics were completely hazed over (not cloudy as in the new 150s). I haveseen this in other CDP-C900s and CDP-C15ESDs. It has also | ||
Sony | CDX7580 | LAMPS BLINKING WHEN ACC TURNED OFF THEN ON | Lamps blinking and no functions. If connect power to ACC wireand memory wire at the same time no problem. If switch 501 (accessorychange) was off it would only blink once then ok). | ||
Sony | CFS3300 | HISSING NOISE IN ONE CHANNEL | Hissing noise in one channel. | ||
Sony | TCWR620 | CASSETTE DOOR(S) WON'T OPEN AND/OR NEITHER DECK WORKS | Cassette door on one side (Deck B) would not open because headassembly was not disengaging from Play position. Then found that theother Deck (A) would not go into any function (although the door wouldopen). Front panel did light up normally and capstan | ||
Sony | KV25XBR | FUSE BLOWS WHEN UNIT IS PLUGGED IN | Blows F-601 7A/125V. As soon as unit is plugged in, fuseblows. |