SonyXR430NO POWER (FOUND D579 DEFECTIVE) No power but unit beeps when buttons are pressed.
SonyXR3200SERVICE MANUAL CORRECTION: HEAD AZIMUTH ADJUSTMENT SCREWS Supplement-1 showing screws for the azimuth adj. is wrong.Specifically, the drawing in the supplement would lead you to believe thatthe 2 screws towards the front of the unit are for adjusting azimuth inthe forward direction, and the 2 screws towards the
SonyXR3050HARNESS SOCKET BROKEN; PART IS "NOT SUPPLIED" Cust dropped unit damaging cord receptacle. No other damageto unit. Part listed as not supplied on page 28 (next to Ref 62).
SonyEXR18SERVICE MANUAL CORRECTION: HEAD AZIMUTH ADJUSTMENT SCREWS Supplement-1 showing screws for the azimuth adj. is wrong.Specifically, the drawing in the supplement would lead you to believe thatthe 2 screws towards the front of the unit are for adjusting azimuth inthe forward direction, and the 2 screws towards the
SonyCDXC590OPTICAL PICKUP/SERVO BOARD INCOMPATIBILITY (KSS-410A/313A) The unit came in for service with type KSS-313A opticalpickup, which was defective. The type shown in the service manual isKSS-410A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit.
SonyCDXC490OPTICAL PICKUP/SERVO BOARD INCOMPATIBILITY (KSS-410A/313A) The unit came in for service with type KSS-313A opticalpickup, which was defective. The type shown in the service manual isKSS-410A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit.
SonyCDX91NO ANALOG AUDIO WHEN CONNECTED TO XDP-U50D OR MDX-U1 When connected to the XDP-U50D or MDX-U1, there is no audio CDaudio if the analog connection is used (digital connection is OK). Inreality, the audio is present on the CDX-91 analog output but the XDP-50Dor MDX-U1 is not selecting it. Problem occurs ev
SonyCDX600DSPOPTICAL PICKUP/SERVO BOARD INCOMPATIBILITY (KSS-313A/410A) The unit came in for service with type KSS-410A opticalpickup, which was defective. The type shown in the service manual isKSS-313A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit. Is there a pa
SonyCDX5490OPTICAL PICKUP/SERVO BOARD INCOMPATIBILITY (KSS-410A/313A) The unit came in for service with type KSS-313A opticalpickup, which was defective. The type shown in the service manual isKSS-410A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit.
SonyCDX5470OPTICAL PICKUP/SERVO BOARD INCOMPATIBILITY (KSS-313A/410A) The unit came in for service with type KSS-410A opticalpickup, which was defective. The type shown in the service manual isKSS-313A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit. Is there a pa
SonyCDX5290OPTICAL PICKUP/SERVO BOARD INCOMPATIBILITY (KSS-410A/313A) The unit came in for service with type KSS-313A opticalpickup, which was defective. The type shown in the service manual isKSS-410A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit.
SonyCDX5290NO AUDIO (FOUND AMP IC303 DEFECTIVE) No audio.
SonyCDX5090OPTICAL PICKUP/SERVO BOARD INCOMPATIBILITY (KSS-410A/313A) The unit came in for service with type KSS-313A opticalpickup, which was defective. The type shown in the service manual isKSS-410A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit.
SonyCDX5090RANDOMLY CHANGES STATIONS OR SCANS DISC BACKWARDS Unit changes stations by itself. Disk skips or countsbackwards when it hits any bump.
SonyCDX5070OPTICAL PICKUP/SERVO BOARD INCOMPATIBILITY (KSS-313A/410A) The unit came in for service with type KSS-410A opticalpickup, which was defective. The type shown in the service manual isKSS-313A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit. Is there a pa



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.