Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Mitsubishi | EE3 | Dead | Cct prot o/c - uprated to 3.15A from 2A also could be start up res R915 15R 2W, R922, R921 & R902 22k 2w | ||
Mitsubishi | EE3 | Dead | AVN5-KIT is available when Q552 has gone s/c - includes R713 1k, R726 5k6, Q552 2SD1556, Q901 S2000N, R508 3k9 5w, R991 4R7 10w, D909 RD3.0FB2 zener, an additional cap C720 22pf | ||
Mitsubishi | EE3 | Crushed whites | Q952 8v reg dry joints | ||
Mitsubishi | EE3 | Bank raster/no sound - OSD ok | Z953 1.6A cct prot. Has been uprated to 3.15A in sets incorporating sat Rx | ||
Mitsubishi | EE2 CT14MS1L | Stuck in AV mode | Check for cracks around tuner lugs | ||
Mitsubishi | EE2 | black line down lh side | R571 560R 1w o/c | ||
Mitsubishi | CVC800 | Colour - has hanover bars. | C307 ( 10uf ) tant. | ||
Mitsubishi | CTV2533 | Destruction of line TR ( 2SD1877 ) int | Remove T551 retin & replace replace STR59041 Q901 | ||
Mitsubishi | CTAV1B | Int reverts to st/by (aft 30mins) | CRT appears to have flashed over by spark gap - check aquadag earthing | ||
Mitsubishi | CT37C2STX | St/by only | C959 470µ 16v & C956 2200µ 25v & check R956/ 986 for dry joints | ||
Mitsubishi | CT37C2STX | Dead | blown 5A wickman fuse from sec of chopper Trfmr Z950 | ||
Mitsubishi | CT3703STX | No pic - ok thro' scart | Check for dry joints in IF can | ||
Mitsubishi | CT3703STX | E/W & width | CHECK R5005 / R5006 FOR DRY JOINTS | ||
Mitsubishi | CT3703STX | Dead - LOPTr s/c | LOPTr 2SD1879 replaced & C908 10µ 100v, C909 47µ 50v | ||
Mitsubishi | CT3701TX | Dead & tripping | Dry joint on 47µ 200v cap in HT rail |