MitsubishiCT29B2STXTrippingCheck C906 47µ 63v & C909 2µ2 63v
MitsubishiCT29B2STXTrippingR916 22k
MitsubishiCT29B2STXRed flaringD655 (1N4148) on the CRT base panel leaky.
MitsubishiCT29B2STXNo N-S correctionQ4009 2SA950Y on PCC board o/c.
MitsubishiCT29B2STXNICAM has intermit crackledry joints in IF can
MitsubishiCT29B2STXN/S dist & won't adjQ4009 2SA950 o/c
MitsubishiCT29B2STXGOES TO SECAM WHEN PLAYING VCRNFF-SELECT PAL FOR ALL VCR PROGS
MitsubishiCT29B2STXFlaring pic modRemove R606,607,608. - change R609 to 56ohms
MitsubishiCT29B2STXE/W FAULTY ADJUSTMENTS ON PCC BOARD DON,T WORKREPLACE Q4009
MitsubishiCT29B2STXDead - Q901 s/c.Fit mod kit ( wVe 77901 ) R901 , D908 , Q901 , C908 to 2700pf , C966.
MITSUBISHICT29B2STXCUTS OUT WHEN COLDREPLACE C906 47MFD50V
MitsubishiCT29AV1DPINT SOUND MUTE WHEN COMING OFF STANDBYREMOVE C368
MITSUBISHICT29AV1DPINT SOUND MUTE WHEN COMING OFF STANDBYREMOVE C368
MitsubishiCT29AT5sound slow to come on from coldC9F4 1000µ leaky in psu
MitsubishiCT29AT5offL551 3µ3 choke in series with base of lop tr o/c



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.