Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Mitsubishi | CT25M1TX | Dead - psu working | crack in print coll of lop tr - also change C906 47µ, C905 470µ | ||
Mitsubishi | CT25M1STX | BLANK/NO VIDEO | Q702 JC501 | ||
Mitsubishi | CT25M1 | Juddering raster | C906 4µ7 25v chopper dr cap | ||
Mitsubishi | CT25B3STX | Pic blanks out into a small square | replaced C965,C970,C987,C974,C718. | ||
Mitsubishi | CT25B3STX | No E-W corr | IC551 TEA2031 | ||
Mitsubishi | CT25B3STX | Field o/p IC have short life | Fit MITSIKIT1 & check C906 47µ 50v, C909 change from 2µ2 to 10µ, D907 3v 1w zener & C960/956 1000µ 35v, C452 220µ 35v & dry joints around crt yoke & scan coils plug | ||
Mitsubishi | CT25B2STX | Smeary video esp when cold | Check/replace caps in IF can | ||
Mitsubishi | CT25B2STX | Several attempts reqd to sw on & HT high initially | C909 2.2uF in primary of PSU. | ||
Mitsubishi | CT25B2STX | No sound | Format EEPROM as per manual | ||
Mitsubishi | CT25B2STX | Nicam dropout with crackling | Dry joints IF unit | ||
Mitsubishi | CT25B2STX | FRAME COLLAPSE | REPLACE IC451 | ||
Mitsubishi | CT25B2STX | FIELD COLLAPSE , NO 30V RAIL | IC551 ( EW ) & R976 , ALSO CHECK Z551 | ||
Mitsubishi | CT25B2STX | Field collapse - replacement of FOP chip | When replacing failed IC451 TDA8178S check elects in field & psu ccts; note TDA8178 nla - use TDA8171 & mod kit usually supplied with it | ||
Mitsubishi | CT25B2STX | Field collapse | IC451 TDA8178S - if TDA8171 used mod reqd | ||
Mitsubishi | CT25B2STX | Dead - Q901 s/c. | Fit mod kit ( wVe 77901 ) R901 , D908 , Q901 , C908 to 2700pf , C966. |