MitsubishiCt25B2STXbuzz on sound - flat pic0.47µ 50v electrolytic in if and dry joints in if
MitsubishiCT25AVIBDSSlow startup.Change C955 ( 2200uf )
MitsubishiCT25AVBDS EE3Int sw on/ off - G LED lights but no pic/sound (no line drive)C956 470uF 6.3v in secondary power supply circuit, close to IC951
MitsubishiCT25AV1BS EE3No E/W or width control (after CSD3 470n replaced)L504 burnt & shorted windings - rewound with 493 turns - also check TDA2013A E/W chip
MitsubishiCT25AV1BS EE3Field collapseTDA8171 & R516 0R82 1/2w o/c
MitsubishiCT25AV1BS EE3Dead - off with burning smell - green LED perm litCSD3 470n 400v o/c - looks stressed cause of trouble. Also R510 100R 1/2w o/c - also replaced TEA2031A
MitsubishiCT25AV1BS EE3Blank raster with soundVid signal enters pin 42 IC201 but no o/ps - eventually found due to no 12v crt base - R514 0R82 1/2w safety res o/c
MitsubishiCT25AV1BSNo sound - pic okreset eeprom settings from infomation provided by Darren Hoskin & Graham Cooke
MitsubishiCT25AV1BDS EE3Int blows LOPTr at sw on from cold & lack of height/int contrast from coldC956 6.3V 470uF in 5V supply.
MitsubishiCT25AV1BDSService mode & EEPROM settingsSwitch on with mains switch and press service microswitch, select button 9 on the remote within 5secs. You will now be in the service mode. Use the buttons on the remote control for the following adjustments: * to toggle between adjustment displays 1 cancel; 2 increase adjustment code; 4 decrease data value; 6 increase data value; 8 decrease adjustment code; 9 adjustment mode on; 0 write to the eeprom( press this to write your changes to the eeprom) Here are the options- TUN 0; SAT 1; AUD 10; ATS 1; STD 1; SYS 1; AV1 2; EEX -; SPK 1; EEP -; ABG 02; A1 02;AL 00; ADK 15; MNP 70; TXT -; FFT 1; VOL 74;HYP 1; SCP 20; FMP 23. not all options appear to be available to some models. Adjustments in the VCJ mode will be in default mode and it will be necessary to observe display in order to set-up width height ew etc.
MitsubishiCT25AV1BD EE3Dead - LOPTr s/cTEA2031A E/W chip IC551 faulty, R510 100R 2w overheating due to L501 6800uH shorted turns
MitsubishiCT25AV1BD EE3Dead - Green LED litchange C702 to 10uf & C955 to 3300uf also change R702 R213 & R214 from 220R to 1k & reset eeprom
MitsubishiCT25AV1BD EE3Blank raster with no sound or osdNo 8v - fit kit 8vREG-KIT from SEME
MitsubishiCT25AV1BDField collapseD561 s/c on E/W IC & R516 o/c
MitsubishiCT25AV1BSound intIC202 TEA6415C faulty (draws excess current) & replace 8v reg Pt no MITS8VREGKIT



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.