MitsubishiCT21A3STXSOUND MUTES INTQ1A1 ON DET PCB Pt No 260P543050
MitsubishiCT21A3STXPattern obliterates sound/pic - ok via scartC9, 13, 21 & 26 0µ47 in IF unit
MitsubishiCT21A2STX etcDead - LOPTr Q522 s/cC905 (470µF, 35V), C906 (47µF, 50V), C909 (2.2µF, 50V) and C920 (100µF, 25V).Note that the transistor type varies with screen size, With a 21in. tube it's type 2SD1877, part no, 260P606010; with a 25in, tube it's type 2SD1878 (part no, 260P607010) while with a 29in. CRT it's type 2SD1879 (part no. 260P608010),
MitsubishiCT21A2STXDead - Q901 s/c.Fit mod kit ( wVe 77901 ) R901 , D908 , Q901 , C908 to 2700pf , C966.
MitsubishiCT21A2WHINE ON NICAM RECEPTION ONLYLINK C3346 & C3342 CATHODES
MitsubishiCT2155STX CT215PATTERNING ON PIC FROM COLDC920 ( 470uF ) C925 ( 10uF ) & D/J around IC902
MitsubishiCT2155STXHerringbone patterningCheck dry joints IF module, or caps around 12v reg IC902 & caps in psu pri
MitsubishiCT2155STXherringbone patternC920 470µ 25v
MitsubishiCT2155Int blank raster.Drys around the SAW filter or coils L4/5 , if not mod kit AFT1 mits
MitsubishiCT2155Ghosting or ringing.Drys around the SAW filter or coils L4/5 , if not mod kit AFT1 mits
MitsubishiCT2153STXNO GREEN ANALOGUE DISPLAYFRONT MICRO ic.701
MitsubishiCT2153STXNo chan or analogue value storeCheck pin 2 IC702 EEPROM chip. If not 30v then check C962 100µ 50v
MitsubishiCT2153STXLines across top half of pic - clears when heatedsec PSU caps C920 470uF/25V, C925 10uF/25V, C923 100uF/10V, C922 100uF/25V
MitsubishiCT2153STXInt fluctuating pic with bright flashes for first 1/2 hrGlue on VC/RGB/CTI pcb at top bracket become resistive - remove glue
MitsubishiCT2153STXDead with red LED lit110v prot zener s/c. Changed C908 10µ 100v & C909 47µ 50v & STR59041 & check hi value res in psu pri



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.