MitsubishiCT2125TXDead.D909 ( 3v zener ) s/c.
MitsubishiCT2125TXDead - standby light flashing.HT @ 35v , D961 ( 6.2v zener ) leaky.
MITSUBISHICT2124BMNOT SWITCHING ON FROM COLDREPLACE C964 100MFD50V
MitsubishiCT2124BMLoss of tuning memorycheck IC702 for 5v at pin1 & -30v at pin 2. If missing check back to psu, if ok replace chip.
MitsubishiCT2124BMDeadC962 100µ & C974 10µ in -30v supply6had leaked & corroded adjacent print, also C965 220µ leaky in 12v supply
MitsubishiCT2124BMDeadC964 100µ50v o/c
MitsubishiCT2117BMCol cycles thro' auto grey scale at sw on with flashing linesCaused by High HT - C911 33µ 50v, C910 33µ 50v & C913 100µ all hi esr
MitsubishiCT2101TXst/by onlyht low at 37v. C910 & 911 1µ 50v
MitsubishiCT2101TXNo pic - no htrs crtR670 on crt base dry joints
MitsubishiCT2101TBlank raster & no sound.R178 o/c , or o/c print between R178 & Q241.
MitsubishiCT2101Smelly smoke.
MitsubishiCT2101Poor remote operation.Filter coil L992 replace with Mod type.
MitsubishiCT2027TXSound - int or no sound.High res connection on IC351 holder.
MitsubishiCT2027TXInt or no colour.D209 ( 1S2076 ) check by replacement.
MitsubishiCT2023BDead / int deadDry joints line dr tfmr & R581



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.