MitsubishiC2857BDead with st/by light flashingAll PSU sec volts ok - line dr at LOPTr base dist - Q501 faulty (OK tested out of cct)
MitsubishiC25M2TXField collapseAN5521 FOP chip & C454 100µ 35v hi esr
MitsubishiC25D7BSlow start up, no Txt, juddering pic & vol slowEEPROM faulty Pt no MITS274P747010 & change IC701 Pt no MITS274P755050
MitsubishiC25D7BNo surround sound - when selecting in menu it shows "OFF" & can't be turned back onSoftware bug - select special menu & ensure "Standard TV" is set to "Off", sw off for 30 secs. Sw back on & Surround sound can now be set
MitsubishiC25D7BNO SURROUND SOUNDSELECT SPECIAL MENU,ENSURE "STANDARD TV" IS "OFF" SWITCH OFF FOR 30 SECS
MitsubishiC25C7BNo pic aft 5-10 mins - sound okDry joints Xtal resonator X701
MitsubishiC25C7BINT NO GREEN LOOKS LIKE CRTREPLACE IC660 ON CRT BASE
MitsubishiC25C7BInt no green aft 30 minsIC660 TEA50101B on crt base
MitsubishiC25C7BFRAME COLLAPSE AND NO SOUNDREPLACE Z551, D507, AND IC551
MitsubishiC25C7BField collapse & no soundZ551 o/c due to D507 s/c & IC551 E/W chip s/c pin 6
MitsubishiC25C7BDead - Green LED fast flashing - after psu repairQ901, Q552, D909 s/c, R991 o/c, C914 47µ low cap & Q501 leaky
MitsubishiC25C7BCol flashes on screen, col sat varies - intDry joint Chroma Xtals X601 & 602
MitsubishiC25A4STX Euro 4Dead , Line OP transistor SC.Replace C906 47uF 63v , R901 4R7 10W Q901 , IC901 , D907 , D908 ( both RD3.OFB1 ) and C975 47uF 63V.
MitsubishiC2557BNo Menu, OSD or able to acess service modeIC702 EEPROM Mits274P747010
MITSUBISHIC21T7BFINE HORIZONTAL LINES ON SCREENREPLACE FRAME IC951 IC**TDA8171



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.