MitsubishiEuro 4Dead - high HT of 190v (156v) & LOPTr s/cCheck C908 10µ 100v & IC901 STR59041 & C909 47µ 50v
MitsubishiEuro 4Dead - fuse o/cSTR59041 s/c caused by leaky JC501R Power Sw tr (use 2SC1815 in lieu)
MitsubishiEuro 4DeadLOPTx s/c between pins 2 & 7
MitsubishiEuro 4DeadNo psu activity - chopper tfmr o/c winding between pins 5 & 6
MitsubishiEuro 4DeadQ552 2SD1877
MitsubishiEuro 4DeadSTR59041 & R2M diode
MitsubishiEuro 4Black dots & dashes across picDry joint pin 3 IC902 12v reg
MitsubishiEuro 3St/by onlyLOPTx pins 1&2 s/c to pin 7 - replace LOPTx - HR7461
MitsubishiEuro 3Replacement of STR4411SMake sure use same suffix chip
MitsubishiEuro 3Int or perm deadCheck R915/916 start up resistors 2k2 3w
MitsubishiEuro 3DeadR901 4R7 5w o/c - no other fault apparent
MitsubishiEuro 14SF CT25A5STXhor lines across screenC955 dry joints
MitsubishiEuro 14SF CT25A5STXField collapseZ551 cct prot o/c, IC5E1 TEA2031A on E/W pcb s/c but replacement failed shortly after replacement. L555 shorted turns (Pt no SEME TPAR2343)
MitsubishiEuro 14SFno / int sigsdry joints on lead by PLL IC
MitsubishiEuro 14SFField collapse (pic blanked)Z551 315mA fuse in LOPTx 27v derived supply o/c, IC5E1 TEA2031A EW corr chip faulty - replaced but overheats. Possible causes - L554/5



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.