MitsubishiEuro 14SFdead or int deadC914 47µ 35v is sus also C905 470µ 25v
MitsubishiEuro 14 CT25M3LTXField collapse - caused by FOP chip AN5521 which failed again shortly after replacementC560 3300µ 35v in 27v supply seems to have been cause
MitsubishiEuro 14 CT21M3TX Dead - but goes in & out of st/byHas 110v on LOPTr but no line drive dry joints IC951 - also check for dry joints on other regs
MitsubishiEuro 14Snowy/blank pic, no OSD, no tuningNo field pulses pin 27 IC701. Replace Q707/8 DTA124ES
MitsubishiEuro 14Blank screen - no sound (Green LED lit)EEPROM IC702 faulty - check for 5v at pin 8 & data on pins 5 & 6 first
MitsubishiEuro 12 CT29B2STXN-S faultyQ4009 -30v reg on separate board near LOPTx - use BC640 in lieu
MitsubishiEuro 12 CT29B2STXField collapseFOP chip - comes as a kit as orig chip NLA - also check C906 47µ 63v, C909 10µ 63v, C452 220µ 35v
MitsubishiEuro 12 CT25M3TXBlank raster - ok via scart - eeprom IC702 X24C04P faulty
MitsubishiEuro 12 CT25A4STXField linC454 4µ7
MitsubishiEuro 12 CT25A3STXNo Txt, Nicam & wide picIC702 EEPROM corrupted - check caps in pri C906/909 & sec of psu when resetting EEPROM
MitsubishiEuro 12 CT21A2STXSlow start up for a period of days - then died C906 47mfd 50v & C920 100mfd 15v, IC901 TEA2261, chopper tr Q901 2SD1887, FOP chip IC451 TDA8178S (TDA8178S nla - fit TDA8171 & replace C457 with 0.22mfd & 1R5 in series. Kit available pt no H27P014020
MitsubishiEuro 12Won't tuneHset won't work on Menu/Ch.Preset/AV etc - dry joints Tr DA2 in hset
MitsubishiEuro 12Weak/dist video - ok on scartDry joints in IF can - comes & goes when tapped
MitsubishiEuro 12Trips - in overvolt modeD907 RD3.0FB1 zener leaky
MitsubishiEuro 12TrippingR916 22k o/c



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.