SonyCCDV11UNIT WILL NOT LOAD TAPE Unit would not accept tape. Cassette housing would begin todesend-stop and then eject tape. Symptom was similar to bad reelsensors. Replaced sensors - same problem. Loaded tape manually withpower supply and pressed Play, drum took off and then shut d
SonyHST616SERVICE MANUAL CORRECTION On page 7 of the service manual, it indicates that TP-101should be grounded in order to do the tape speed adjustment. This isincorrect.
SonyKV32XBR15"F" BOARD CIRCUIT CORRECTION, SEE SERVICE BULLETIN 66R1 There is a discrepancy in the F board schematic diagram.When the board is ordered, it comes with a softstart circuit consisting ofQ-604, R-610, R-616 and C-613. This circuit is not in the service manual. -HQ COMMENTS: There was a production change when
SonyKV32XBR10"F" BOARD CIRCUIT CORRECTION, SEE SERVICE BULLETIN 66R1 There is a discrepancy in the F board schematic diagram.When the board is ordered, it comes with a softstart circuit consisting ofQ-604, R-610 and C-613. This circuit is not in the service manual. -HQ COMMENTS: There was a production change when the XB
SonyKV27XBR15"F" BOARD CIRCUIT CORRECTION, REFER TO SB # 66R1 There is a discrepancy in the F board schematic diagram.When the board is ordered, it comes with a softstart circuit consisting ofQ-604, R-610 R-616 and C-613. This circuit is not in the service manual. -HQ COMMENTS: There was a production change when
SonyCCDV101DIGITAL TILTER PICTURE DISTORTED Digital titler picture is distorted. Picture has black hor-izontal lines. If you turn the power off, then on immediately picture maylock on.
SonyDTC700REPLACED DRUM ASSEMBLY - DRUM DOESN'T SPIN After replacing drum assembly, the new drum did not spin.Checked all drive signals to drum - ok. Put old drum back and still nospin.
SonySLV575UCCANNOT PROGRAM CLOCK OR TIMER Cannot program clock or timer. Found no 32Khz clock at IC-201pins 10 and 11 (real time clock).
SonySLV353UCWON'T TURN OFF DISPLAY (NO FUNCTIONS OPERATE) When unit is plugged in (power on), immediately comes on andwon't turn off, no functions operate, won't load a tape. Looks like microis locked up. Note: When the cam motor was taken out of the unit and a DCvolt applied to it, it intermittently ran for
SonyCDPC205DAMAGED LOADING GEAR Unit will either not open and close properly or the drawerwill close, open slightly and then reclose.
SonyCDPC305LOADING GEAR Unit will either not open and close properly or the drawerwill close, open slightly and then reclose.
SonyCDPC9ESDDISC DOES NOT GO INTO UNIT Some discs are jamming when they go into the magazine. -HQ COMMENTS: A similar problem was found in a CDPC100. As mentioned inFPR No. L1070, some wear and scratches on the metal spring inside themagazine were found. By filing the contact area on the s
SonyKX2501AFOLDOVER AT TOP (VERTICAL), REPLACED C518 There is a foldover at top of screen (vertical).
SonyKV1554RTHIRD CHANNEL POSITION STUCK IN HIGH BAND The third channel position (normally channel 4) was stuck inthe HIGH band. All other channel positions worked properly. The problemwas caused by D-005 on the M-1 board. The diode checked good with a DVMin the diode test position. A common failure wit
SonyDTC75ESINCORRECTLY WIRED DAT ERROR INDICATOR JIG CONNECTOR CABLE The connector cable used to interface the error indicator jig(P/N J-8000-001-A) to the unit is wired backwards. This causes all threeleds to steadily light when the A head is monitored and no leds will lightwhen monitoring the B head. This has been ver



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.