Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | HCDH150 | NO POWER - REPLACED +5V REGULATOR AND ZENER D735 | No power. | ||
Sony | HCDC50U | CD LOADING TOO FAST - REPLACED IC414 | Travels to fast causing cd's to shift out of tray. | ||
Sony | HCDC33 | UNIT FLASHES INITIALIZING - CD SECTION NEEDS ALIGNMENT | When power plug is pulled out and plugged back in unit flashesinitializing on display until CD mech cycles through all drawers. If CDdoes not cycle due to a jam, the unit will not come out of theinitializing cycle. Unit will turn on but when it is powe | ||
Sony | HCDC33 | CD JAMMED - REALIGNED MECHANISM | Mechanism jammed. Trays 333-337 slide into main tray, 310, inthis case tray 337 did not latch into 310 causing the mech to jam. | ||
Sony | DTC700 | NEW SLANT BLOCK ASSY LEFT/RIGHT NOT WORKING | Upon installation of the new slant block assy, left/right,they are not sliding freely in the slot on the chassis. When screw 628 istightened in place with ref 606, plate assy, loading, the two pieces arepinched together. | ||
Sony | DTC59ES | EATS TAPES - TIGHTENED CAPSTAN MOUNT SCREWS | Unit eats tape at beginning of 120 min. tape in long mode.Found tape would ride down on capstan. | ||
Sony | CDPC615 | NO TRAY ROTATION OR BU ASSM CHUCKING - REPL FLEX CABLE | Tray would never rotate. BU assm would never chuck. | ||
Sony | CDPC335 | TRAY MOTOR SPINNING BACKWARDS - REPLACE TABLE MOTOR | Ran into this problem 5 times in past 3 weeks. Removed traymotor. Old motor is installed with lable on motor facing up. If newmotor is installed with lable facing up, motor will spin backwards andtray will not function properly. | ||
Sony | CDP590 | INCORRECT PART # J401 - CORRECT PART #156692111 | The microfiche service infomration gives J401 as part #1-569-442-11. This is incorrect. | ||
Sony | XRU880 | DEAD UNIT (REPLACED Q504 AND D513) | Unit was dead. Master control IC was on but would not powerup unit (pin 5 stayed low). Bus On pin 38 would pulse low 3 times whenunit was powered up. Data and clock lines would show initial activity. | ||
Sony | XRU770 | DEAD UNIT (REPLACED Q504 AND D513) | Unit was dead. Master control IC was on but would not powerup unit (pin 5 stayed low). Bus On pin 38 would pulse low 3 times whenunit was powered up. Data and clock lines would show initial activity. | ||
Sony | XRC410 | MECHANISM GEAR ALIGNMENT PROCEDURES AVAILABLE IN SUPP. #1 | The mechanism in this model uses gears and encoders which mustbe aligned properly in order for the mechanism to work, but the manualdoes not detail the alignment procedure. | ||
Sony | XRC210 | MECHANISM GEAR ALIGNMENT PROCEDURES AVAILABLE IN SUPP. #1 | The mechanism in this model uses gears and encoders which mustbe aligned properly in order for the mechanism to work, but the manualdoes not detail the alignment procedure. | ||
Sony | CDX5470 | OPTICAL PICKUP RECEIVED FROM NPC DOES NOT WORK IN UNIT | The unit came in for service with type KSS-410A opticalpickup, which was defective. The type shown in the service manual isKSS-313A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit. Is there a pa | ||
Sony | CDX5270 | OPTICAL PICKUP RECEIVED FROM NPC DOES NOT WORK IN UNIT | The unit came in for service with type KSS-410A opticalpickup, which was defective. The type shown in the service manual isKSS-313A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit. Is there a pa |